Garland 7000 Additional Errors, Problem, Possible Cause, Measure, Operation lamp flashes

Models: 7000

1 20
Download 20 pages 25.54 Kb
Page 11
Image 11

Additional Errors

 

 

Problem

 

Possible Cause

 

 

Measure

 

 

 

 

 

 

 

 

 

 

Code

No.

 

No

 

 

No

 

W

 

 

 

 

 

 

 

 

No

 

 

Operation lamp is continuously “ON”

 

 

 

 

Cooking platform does not

 

 

 

 

Compare on another

 

 

S20

U10

Non induction type pan

 

M10

cooking platform and with

E

 

heat enough

 

 

 

 

 

 

 

 

an induction type pan

 

 

 

 

U200

1 phase is missing

 

M200

Check mains cable

L

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

U12

Power board defective

 

M12

Replace power circuit

L

 

 

 

 

board

 

 

 

 

 

 

 

 

 

 

 

U14

CPU-circuit board

 

M14

Replace CPU-circuit board

L

 

 

 

defective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooking platform

 

Operational control

 

 

 

 

 

S21

continuously on

U50

 

M50

Check operational control

L

 

defective

 

 

 

maximum power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U14

CPU-circuit board

 

M14

Replace CPU-circuit board

L

 

 

 

defective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U12

Power circuit board

 

M12

Replace power circuit

L

 

 

 

defective

 

board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S22

Empty cooking platform

U220

Pan detection defective

 

M220

Check pan detection

L

 

switches “on“

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Little metallic objects are

 

 

 

 

 

 

 

S23

heated on the cooking

U220

Pan detection defective

 

M220

Check pan detection

L

 

 

platform

 

 

 

 

 

 

No.

 

 

 

Operation lamp flashes

 

 

 

 

 

 

 

 

 

 

 

 

S24

Cooking platform does not

U240

Pan too small (Diameter

 

M240

Use appropriate pan

E

 

heat at all

less than 12cm, 4.75”)

 

 

 

 

 

 

 

 

 

 

 

 

 

U200

1 phase is missing

 

M200

Check connection of

L

 

 

 

 

mains cable

 

 

 

U220

Pan detection defective

 

M220

Check pan detection

L

 

 

 

 

 

 

 

 

 

 

 

 

U241

Short circuit on generator

 

M241

Replace or repair

L

 

 

 

 

generator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Legend: W = Who should complete “Measure”

E = End user L = Supplier

 

 

 

Part # 4526029 (02/22/11)

Page 11

Page 11
Image 11
Garland 7000 service manual Additional Errors, Problem, Possible Cause, Measure, Operation lamp flashes