Adjustments

This induction unit has been correctly adjusted by the manufacturer. Any adjustments have to be made with caution. Please pay attention to the following points:

1.Note the original position of the poti’s: remember the number of turns you make.

2.Errors can occur after wrong adjustments

3.Only small corrections can be made with adjustments

Generator Type

The generator type is adjusted in the binary code with the DIP-switches 5 to 8 on the CPU-circuit board

Switch Position

DIP-Switch for

8

7

6

5

generator type

 

 

 

 

 

 

 

 

 

0

 

 

 

 

1

 

 

 

ON

2

 

 

ON

 

 

 

 

 

 

3

 

 

ON

ON

4

 

ON

 

 

5

 

ON

 

ON

 

 

 

 

 

6

 

ON

ON

 

7

 

ON

ON

ON

8

ON

 

 

 

 

 

 

 

 

9

ON

 

 

ON

10

ON

 

ON

 

11

ON

 

ON

ON

 

 

 

 

 

12

ON

ON

 

 

13

ON

ON

 

ON

14

ON

ON

ON

 

 

 

 

 

 

15

ON

ON

ON

ON

Switch Power

Summary: software and generator type

The following list shows the number of types of the various generators.

Please note the positions of the power switches from the above table.

Type

DIP

Switch setting

 

MO/DU 7000, 208V

6 and 8 on

MO/DU 7000, 400V

5 and 8 on

Pan detection

The potentiometer on the rectifier circuit board is used to adjust the pan detection:

Turn clockwise:

acceptance of smaller pans

Turn counterclockwise: only bigger pans are accepted

Power

Only one potentiometer per field is available on the power circuit board to adjust the power:

Turn clockwise:

less power

Turn counterclockwise: more power

Repair by Garland

If the generator has to be repaired by the manufacturer, please enclose an exact description of the error. If possible, use the original package for the return. If it isn’t available, do not use porous material for wrapping (like styropor). This could enter the unit and the electronic parts and is difficult to remove.