SECTION 3 – INITIAL OPERATION

Function control

To check the function controls, the induction generator must be totally connected.

Display

1.The external lamps must be checked.

2.The operation lamp flashes if a coil is not used (Searching function).

3.This procedure must be repeated for every coil.

Pan Detection

To check the pan detection, two pans are needed: one with a diameter of 8cm (3”) and the other with a diameter of 12cm (4.75”) .Only the pan with a diameter of 12cm (4.75”) should be detected. A coil should not start operation when it is not being used.

This procedure must be repeated for every coil.

Power

Place an “induction ready” pan with a diameter of 22-24cm (8.5”-9.5”) onto the coil. Measure the generator power

at maximum level. This should be at the nominal power (tolerance +/- 10%). This procedure must be repeated for every coil.

Fan

Place various pans on the coils and start the generator on the highest level. After a few minutes the fan should start. The fan is controlled by the temperature and starts when the heat sink temperature is about 50ºC/122ºF.

Page 8

Part # 4526029 (02/22/11)

Page 8
Image 8
Garland 7000 service manual Initial Operation, Function control, Pan Detection, Power, Fan