SECTION 3 – INITIAL OPERATION
Function control
To check the function controls, the induction generator must be totally connected.
Display
1.The external lamps must be checked.
2.The operation lamp flashes if a coil is not used (Searching function).
3.This procedure must be repeated for every coil.
Pan Detection
To check the pan detection, two pans are needed: one with a diameter of 8cm (3”) and the other with a diameter of 12cm (4.75”) .Only the pan with a diameter of 12cm (4.75”) should be detected. A coil should not start operation when it is not being used.
This procedure must be repeated for every coil.
Power
Place an “induction ready” pan with a diameter of
at maximum level. This should be at the nominal power (tolerance +/- 10%). This procedure must be repeated for every coil.
Fan
Place various pans on the coils and start the generator on the highest level. After a few minutes the fan should start. The fan is controlled by the temperature and starts when the heat sink temperature is about 50ºC/122ºF.
Page 8 | Part # 4526029 (02/22/11) |