SECTION 4 – TROUBLE SHOOTING AND REPAIRS

SECTION 4 – TROUBLE SHOOTING AND REPAIRS

This section includes a list of the main errors, their causes and the respective steps to correct.

Trouble Shooting

Error-Code

 

 

Problem

 

Possible Cause

 

 

Measure

 

Code

No.

 

No

 

 

No

 

W

 

 

 

 

 

 

 

 

 

No

 

 

 

Normal operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No coil current

 

 

 

 

Compare on another

 

1

S01

U10

Non induction type pan

 

M10

cooking platform and with

E

Hardware overcurrent

 

 

 

 

 

 

 

 

an induction type pan

 

 

 

 

U11

Coil defective

 

M11

Check coil

L

 

 

 

 

 

 

 

 

 

 

 

 

U12

Power circuit board

 

M12

Replace power circuit

L

 

 

 

defective

 

board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High coil current

 

 

 

 

Compare on another

 

2

S02

U10

Non induction type pan

 

M10

cooking platform and with

E

Software overcurrent

 

 

 

 

 

 

 

 

an induction type pan

 

 

 

 

U12

Power circuit board

 

M12

Replace power circuit

L

 

 

 

defective

 

board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U13

Error on DIP-Switch-

 

M13

Check DIP-Switch

L

 

 

 

adjustment on CPU

 

adjustment

 

 

 

 

 

 

 

 

 

 

U14

CPU-circuit board

 

M14

Replace CPU-circuit board

L

 

 

 

defective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

S03

Temperature heat sink

U30

Air entrance/exit

 

M30

Clear air transport

E/L

obstructed

 

 

 

 

 

 

 

 

 

 

 

 

U31

Dirty fan/heat sink

 

M31

Clean fan

L

 

 

 

 

 

 

 

 

 

 

 

 

U32

Fan defective

 

M32

Check fan

L

 

 

 

 

 

 

 

 

 

 

 

 

U33

Rectifier circuite board

 

M33

Replace rectifier circuit

L

 

 

 

defective

 

board

 

 

 

 

 

 

 

 

 

 

U34

Sensor Heat sink defective

 

M34

Check sensor and heat

L

 

 

 

 

sink

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U14

CPU-circuit board

 

M14

Replace CPU-circuit board

L

 

 

 

defective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

S04

Temperature cooking

U40

Empty cooking

 

M40

Empty pan

E

platform

 

 

 

 

 

 

 

 

 

 

 

 

 

U41

Interruption of coil sensor

 

M41

Check coil sensor

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

S05

Operational control

U50

Operational control

 

M50

Check operational control

L

Line break

defective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Legend: W = Who should complete “Measure”

E = End user L = Supplier

 

 

 