Useful info about Alarm Contacts in ES42H and ES42P:

ES42 Series Edge Switches

Installation and User Guide (05/05)

4.4 Hardware operated Alarm Contact for monitoring internal power supply

The two screws Alarm Contacts feature, standard on Magnum ES42H and P, provides Normally Closed (NC) contacts to which the user can attach one sets of status monitoring wires at the green terminal block. When this option is present, the terminal block for Alarm Contacts is part of the Power Input panel in the Magnum ES42s case. The DC power input connection is in the same panel.

The NC Alarm Contact is held close when there is power on the main board inside of the ES42. This provides a “Hardware operated Alarm” because the NC contacts will open when internal power is lost, either from an external power down condition or by the failure of the power supply inside of the Magnum ES42 Switch.