Click Save to save the changes.
Click Close to return to the SSU main window.
Setting up LAN alerts
To set up LAN alerts:
1 Boot your server from the System Companion CD, then select System Setup Utility from the menu. The System Setup Utility starts.
2 In the SSU main window, under Server Configuration,
3 Click to select the Enable LAN Alerts check box.
4 In the SNMP Community String box, you can type an optional string for the community field in the Header section of the SNMP trap sent for an alert. The string must be from 5 to 16 characters. The default string is public.
5 In the IP Setup box, click either:
■
■
6 If you chose Static IP Setup in the previous step, complete the IP addressing boxes:
■Gateway MAC
■Host IP
■Gateway IP
■Subnet
7 In the Alert IP Address box, complete the IP address of the system you want to receive alerts from this server. If you want the alert to be broadcast to an entire subnet, enter the IP address for the subnet.
8 In the Alert IP MAC Address box, complete the physical Internet address (MAC address) of the system you want to receive alerts from this server. Enter only valid hex values for the Alert IP MAC address.
9 Click Options, then click Configure Event Actions.