Operations

Orca 80-99 Operation and Maintenance Manual

 

 

Operator ControlsThe operator controls for the Orca laminator are

operator position. See Figures 2-1 and 2-2. The names and functions of these controls are as follows:

FRONT CONTROL PANEL

Please note that in each of the control sections there is a Pressure Gauge, an On/Off switch and an Air Pressure Regulator. The Pressure Gauge shows the operational pressure. The On/Off switch turns the control function on or off. The Air Pressure Regulator adjusts the air pressure for the control function.

A. TOP BRAKE CONTROLS - Regulation of the upper unwind shaft brakes.B. TOP CLUTCH CONTROLS - Front upper rewind shaft clutch regulation.C. LAMINATOR ROLL CONTROLS - Regulation of the main laminating rolls.D. BOTTOM BRAKE CONTROLS - Regulation of the front lower unwind brake.

E. BOTTOM CLUTCH CONTROLS - Regulation of the shaft’s lower front rewind clutch.

F.RUN/JOG SWITCH - Changes control of the machine drive from a foot switch operation to continuous run. It also allows the operator to “Jog” the rolls for a short period of time.

G.REV-FWD - This switch controls the direction of the drive system, forward or reverse.

H.SPEED CONTROL - Adjusts the speed of the machine from zero to maximum as the control is turned clockwise.

I.SPEED READOUT - Digital readout of the machine speed and total throughput in either metric or standard units.

J.ON/OFF LAMP (Top Heater) - Denotes whether the top heater controller is on or off.

K.ON/OFF LAMP (Bottom Heater) - Denotes whether the bottom heater controller is on or off.

L.PHOTO EYE LAMP - Denotes whether or not the PHOTO EYE is blocked.M.MAIN POWER LAMP - Denotes whether or not the main power is on the machine.N.MAIN POWER SWITCH - Turns themain power on and off.REAR CONTROL PANEL

A. ON/OFF (Top Heater Controller) - Controls whether or not the top heater controller is on or off.

B.TOP HEATER CONTROLLER - Controls the

upper main roll’s operational temperature and provides a readout of the actual temperature.

C.ON/OFF (Top Fan Bank) - Controls whether or not the top fan bank is on or off.

D.ON/OFF (Bottom Heater Controller) - Controls whether or not the bottom heater controller is on or off.

E.BOTTOM HEATER CONTROLLER - Controls the lower main roll’s operational temperature and provides a readout of the actual temperature.

F.ON/OFF (Bottom Fan Bank) - Controls whether or not the bottom fan bank is on or off.

G.PULL ROLLER CLUTCH CONTROLS- Regulation for the bottom pull roller clutch.

CAUTION:

Use the minimum laminator roll pressure consistent with good results. Excess pressure can damage the laminating rollers.

Page 5 - 4

© GBC Films Group June 2000