Installation Instructions

10MARK HOLES

Select the vent option that your installation will require and proceed to that section:

A. Outside top exhaust

(Vertical duct–314x 10Rectangular)

Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Hood mounting screws (4)

 

 

 

 

 

1334(30hood)

 

 

 

 

 

 

 

1334(30hood)

1634(36hood)

 

 

 

1634(36hood)

 

 

Cabinet front

 

 

 

 

 

 

 

 

 

 

734

 

 

 

Cabinet Bottom

 

 

 

514

514

114

958

334

Vertical duct

 

access hole

 

 

 

12

 

 

138

 

 

 

 

 

Electrical access hole

Wood shims (recessed-

Center

(in cabinet bottom)

bottom cabinets only)

line

 

 

 

 

B.Outside top exhaust (Vertical duct–7Round)

Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Hood mounting screws (4)

1334(30hood)

 

 

 

13

3

(30

hood)

1634(36hood)

 

4

 

16

3

(36

hood)

 

 

4

 

A. Outside top exhaustCabinet front

Cabinet

 

734

 

 

 

bottom

8DIA.

 

9

5

8

Access

114

HOLE

 

hole for 7

 

534

 

 

 

round duct

 

138

 

 

 

 

 

 

 

 

 

 

 

Electrical access

Wood shims (recessed- Center hole (in cabinet bottom) bottom cabinets only)

line

C. Outside rear exhaust

(Horizontal duct–314x 10Rectangular)

Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Wood shims (recessed-bottom cabinets only)

 

Cabinet front

12114

334

Horizontal duct

 

Cabinet

access hole

 

 

514

514

 

bottom

 

1334(30hood)

 

734

 

 

1334(30hood)

1634(36hood)

 

1634(36hood)

Hood mounting screws (4) Center line

Electrical access hole

(in wall)

 

 

D. Recirculating (non-vented ductless– JN327 and RN328, and optional on JV347 and JV367 models only)

Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots.

Since the hood is to be recirculated (not to be vented outside), do not cut out any vent openings in the wall or cabinet bottom.