Installation Instructions
11FOR RECESSED-BOTTOM CABINETS ONLY
Wood shims
•If the cabinets have front, side or back trim, make
2 wood shims the width of the trim and attach them to the cabinet bottom recess on both sides. See Step 10 for marking locations.
12CUT HOLES
Cut holes at marked locations for duct and electrical wiring. For the vertical duct, cut out 3/4″ extra toward the front of the cabinet so you can move the duct freely when installing the hood. It may also ease installation by cutting the hole 101⁄2″ instead of 10″.
13RUN WIRES
Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes.
NOTE: DO NOT turn the power on until installation is complete.
14SCREW IN PARTWAY
Drive a mounting screw (from the hardware packet) partway into each center of the narrow neck of the keyhole slots marked on the cabinet bottom.
15OPTIONAL POWER CORD KIT JXHC1
An optional Power Cord Connection Kit, model JXHC1, is available at extra cost from your GE supplier for installation using a standard
C | Cabinet |
|
L |
| |
|
| |
73⁄4″ |
| wall outlet |
11⁄4″ | (if using cord | |
| connection) |
13⁄4″ dia. clearance hole for optional power supply location
NOTE: If using optional Power Cord Kit JXHC1, feed the power cord through the hole in the top cabinet while raising the hood. Loop any excess length of cord and tie away with a suitable tape or tie.
16FEED IN WIRES
Lift the hood into position and feed the house wiring through the wiring knockout.
14