Installation Instructions
INSTALLING THE WATER LINE (CONT.)
9
CONNECT THE TUBING TO THE REFRIGERATOR
NOTES:
• Before making the connection to the refrigerator, |
be sure the refrigerator power cord is not |
plugged into the wall outlet. |
9CONNECT THE TUBING TO THE REFRIGERATOR (CONT.)
One of the illustrations below will look like the connection on your refrigerator.
Icemaker Models without Water Dispenser
• We recommend installing a water filter if your |
water supply has sand or particles that could clog |
the screen of the refrigerator’s water valve. Install |
it in the water line near the refrigerator. If using |
GE SmartConnect™ Refrigerator Tubing kit, you |
will need an additional tube (WX08X10002) to |
connect the filter. Do not cut plastic tube to |
install filter. |
Remove the screws holding the right side of the access cover. Fold back the cover.
Remove the plastic flexible cap from the water valve
1/4″ Tubing
SmartConnect™ Tubing
Tubing Clamp
1/4″ Compression Nut
Ferrule (sleeve)
Refrigerator
Connection
(refrigerator connection).
Place the compression nut and ferrule (sleeve) onto the end of the tubing as shown. On GE SmartConnect™ Refrigerator Tubing kit, the nuts are already assembled to the tubing.
Insert the end of the tubing into the water valve connection as far as possible. While holding the tubing, tighten the fitting.
For plastic tubing from a GE SmartConnect™ Refrigerator Tubing kit, insert the molded end of the tubing into the water valve connection and tighten compression nut until it is
Fasten the tubing into the clamp provided to hold it in a vertical position. You may need to pry open the clamp.
Water Dispenser Models |
|
Tubing Clamp | 1/4″ Tubing |
|
1/4″ Compression Nut
Ferrule (sleeve)
Refrigerator Connection
SmartConnect ™ Tubing
10 TURN THE WATER ON AT THE SHUTOFF VALVE
Tighten any connections that leak.
Reattach the access cover.
18