Performance Data Sheet
SmartWater™ Filtration System³GE MWF Cartridge
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
Capacity 300 Gallons (1,135 Liters). Contaminant Reduction Determined by NSF testing.
|
|
|
| Average Product | Max Permissible |
|
|
Substance Tested |
| 16)VSHFL½HG | Avg % | Water | Product Water | NSF Reduction | NSF |
for Reduction | AvHUDJH,Q¾XHQW | Challenge Concentration | Reduction | Concentration | Concentration | Requirements | Test Report |
Chlorine Taste and Odor | 2.0 mg/L | 2.0 mg/L ± 10% | 97.5% | 0.05 mg/L | N/A | | |
Nominal Particulate | 7,833,333 pts/mL | At least 10,000 particles/mL | 99.7% | 18,617 pts/mL | N/A |
| |
&ODVV,WRP | | ||||||
Cyst* | 101,000 cysts/L | Minimum 50,000 cysts/L | 99.99% | 1 cyst/L | N/A | | |
|
| WR¿EHrV/¿EHrs |
|
|
|
|
|
Asbestos | 47 MF/L | grHDWHUWKDQPLQOHQJWK | >99% | 0)/ | N/A | | |
Atrazine | 0.009 mg/L | 0.009 mg/L ± 10% | 94.5% | 0.0005 mg/L | 0.003 mg/L | N/A | |
Benzene | 0.016 mg/L | 0.015 mg/L ± 10%± | 96.7% | 0.0005 mg/L | 0.005 mg/L | N/A | |
Carbofuran | 0.08 mg/L | 0.08 mg/L ± 10% | 98.7% | 0.001 mg/L | 0.04 mg/L | N/A | |
Endrin | 0.007 mg/L | 0.006 mg/L ± 10% | 97.1% | 0.0002 mg/L | 0.002 mg/L | N/A | |
Lead @ pH 6.5 | 0.152 mg/L | 0.15 mg/L ± 10% | 99.3% | 0.001 mg/L | 0.010 mg/L | N/A | |
Lead @ pH 8.5 | 0.148 mg/L | 0.15 mg/L ± 10% | 99.3% | 0.001 mg/L | 0.010 mg/L | N/A | |
Lindane | 0.002 mg/L | 0.002 mg/L ± 10% | 99.0% | 0.00002 mg/L | 0.0002 mg/L | N/A | |
Mercury @ pH 6.5 | 0.0058 mg/L | 0.006 mg/L ± 10% | 93.2% | 0.0004 mg/L | 0.002 mg/L | N/A | |
Mercury @ pH 8.5 | 0.0061 mg/L | 0.006 mg/L ± 10% | 93.2% | 0.0004 mg/L | 0.002 mg/L | N/A | |
0.222 mg/L | 0.225 mg/L ± 10% | 99.8% | 0.005 mg/L | 0.075 mg/L | N/A | ||
Tetrachloroethylene | 0.015 mg/L | 0.015 mg/L ± 10% | 96.7% | 0.0005 mg/L | 0.005 mg/L | N/A | |
Toxaphene | 0.015 mg/L | 0.015 mg/L ± 10% | 93.2% | 0.001 mg/L | 0.003 mg/L | N/A | |
0.218 mg/L | 0.210 mg/L ± 10% | 99.5% | 0.0009 mg/L | 0.07 mg/L | N/A |
*Based on the use of Cryptosporidium parvum oocysts.
The following pharmaceutical reduction claims have not been certi¿ed by NSF International or the state of California. Claims tested and veri¿ed by independent laboratory:
|
|
|
| Average Product | Max Permissible |
|
|
Contaminant |
| 16)VSHFL½HG | Avg % | Water | Product Water | NSF Reduction | NSF |
Reduction | AvHUDJH,Q¾XHQW | Challenge Concentration | Reduction | Concentration | Concentration | Requirements | Test Report |
Atenolol | 978 ng/L | N/A | 99.5% | 5.0 ng/L | N/A | N/A | |
Fluoxetine | 907 ng/l | N/A | 99.4% | 5.4 ng/L | N/A | N/A | |
Ibuprofen | 885 ng/L | N/A | 94.1% | 52.3 ng/L | N/A | N/A | |
Progesterone | 1097 ng/L | N/A | 99.5% | 5.0 ng/L | N/A | N/A | |
Trimethoprim | 415 ng/L | N/A | 99.5% | 2.0 ng/L | N/A | N/A |
Application Guidelines/Water Supply Parameters
Service Flow | 0.5 gpm (21.9 lpm) |
Water Supply | Potable Water |
Water Pressure | |
Water Temperature |
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised. See Installation Manual for Warranty information.
Note: While the testing was performed under standard laboratory conditions, actual performance may vary.
Replacement Cartridge: MWF. For estimated costs of replacement elements please call
WARNING
To reduce the risk associated with ingestion of contaminants:
•Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before and after the system. Systems certL¿ed for cyst reduction may be used on disinfected water that may contain ¿lterable cysts. EPA Establishment Number
For conditions of use, health claims certified by the California Department of Public Health, and replacements, see performance data sheet. California Department of Public Health Certification
NOTICE
To reduce the risk associated with property damage due to water leakage:
•Read and follow use instructions before installation and use of this system.
•Installation and use MUST comply with all state and local plumbing codes.
•Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure exceeds 80 psi, you must install a
•Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.
•Do not install on hot water supply lines. The maximum operating water temperature of this ¿lter system is 100º F (38º C).
•Protect ¿lter from freezing. Drain ¿lter when temperatures drop below 33ºF (0.6ºC).
• must be replaced every 6 months at the rated capacity, or sooner if a noticeable reduction in ÀRw rate occurs.
REPLACEMENT
ELEMENT
Tested and cerWL½ed by NSF International against NSF/ANSI Standard 42 and Standard 53 in model GE MWF for the reduction of the claims speci½Hd on the performance data sheet.
25