25
Performance Data SheetSmartWater Filtration System³GE MWF Cartridge

The concentration of the indicated subs tances in water entering the system wa s reduced to a concentration less than or e qual to the permissible

limit for water leaving the system a s specified in NSF/ANSI Standard 42 and Standard 53. System tested and certi fied by NSF International against

NSF/ANSI Standard 42 and Standard 53 for the reduction of substances liste d below.

The following pharmaceutical reduction claims have not been certi¿ed by NSF International or the state of California.

Claims tested and veri¿ed by independent laboratory:

Contaminant
Reduction AvHUDJH,Q¾XHQW
16)VSHFL½HG
Challenge Concentration Avg %
Reduction
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration NSF Reduction
Requirements NSF
Test Report
Atenolol 978 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121587
Fluoxetine 907 ng/l N/A 99.4% 5.4 ng/L N/A N/A J-00121587
Ibuprofen 885 ng/L N/A 94.1% 52.3 ng/L N/A N/A J-00121588
Progesterone 1097 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121589
Trimethoprim 415 ng/L N/A 99.5% 2.0 ng/L N/A N/A J-00121587
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.

Application Guidelines/Water Supply Parameters

Service Flow 0.5 gpm (21.9 lpm)
Water Supply Potable Water Water Pressure 40-120 psi (2.8-8.2 bar)
Water Temperature 33°F-100°F (0.6°C-38°C)
Note: While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: MWF. For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.

WARNING

To reduce the risk associated with inges tion of contaminants:
Do not use wi th water that is microbio logically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems certL¿ed
for cyst reduction may be used on disinfected water that may con tain ¿lterable
cysts. EPA Establishment Number 10350-MN-005.

NOTICE

To reduce the risk associated with property damage due to water leakage:
Read and follow use instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
Do not install if water pressure exceeds 120 psi (8.2 bar). If you r water pressure
exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure .
Do not install where water hammer conditions may occur. If water h ammer
conditions exist you must install a water hammer arrester. Conta ct a plumbing
professional if you are uncertain how to check for this condition.
Do not install on hot water supply lines. The maximum op erating water
temperature of this ¿lter system is 100º F (38º C).
Protect ¿lter from fr eezing. Drain ¿lter when temperatures drop
below 33ºF (0.6ºC).
must be replaced every 6 months at the
rated capacity, or sooner if a noticeable r eduction in ÀRw rate occurs.
For conditions of use, health claims certified by the Californ ia De partment of Public
Health, and replacements, see performance data sheet. California Department
of Public Health Certification #05-1698. The contaminants or other substances
removed or reduced by this water f ilter are not necessarily in a ll users’ water.

Capacity 300 Gallons (1,135 Liters). Contaminant Reduction Determined by NSF testing.

Substance Tested
for Reduction AvHUDJH,Q¾XHQW
16)VSHFL½HG
Challenge Concentration Avg %
Reduction
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration NSF Reduction
Requirements NSF
Test Report
Chlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 97.5% 0.05 mg/L N/A  J-00077703
Nominal Particulate
&ODVV,WRP 7,833,333 pts/mL At least 10,000 particles/mL 99.7% 18,617 pts/mL N/A  J-00077704
Cyst* 101,000 cysts/L Minimum 50,000 cysts/L 99.99% 1 cyst/L N/A  J-00100036
Asbestos 47 MF/L WR¿EHrV/¿EHrs
grHDWHUWKDQPLQOHQJWK >99% 0)/ N/A  J-00077707
Atrazine 0.009 mg/L 0.009 mg/L ± 10% 94.5% 0.0005 mg/L 0.003 mg/L N/A J-00077708
Benzene 0.016 mg/L 0.015 mg/L ± 10%± 96.7% 0.0005 mg/L 0.005 mg/L N/A J-00077717
Carbofuran 0.08 mg/L 0.08 mg/L ± 10% 98.7% 0.001 mg/L 0.04 mg/L N/A J-00077718
Endrin 0.007 mg/L 0.006 mg/L ± 10% 97.1% 0.0002 mg/L 0.002 mg/L N/A J-00100039
Lead @ pH 6.5 0.152 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00077722
Lead @ pH 8.5 0.148 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00077723
Lindane 0.002 mg/L 0.002 mg/L ± 10% 99.0% 0.00002 mg/L 0.0002 mg/L N/A J-00077726
Mercury @ pH 6.5 0.0058 mg/L 0.006 mg/L ± 10% 93.2% 0.0004 mg/L 0.002 mg/L N/A J-00100037
Mercury @ pH 8.5 0.0061 mg/L 0.006 mg/L ± 10% 93.2% 0.0004 mg/L 0.002 mg/L N/A J-00092355
P-Dichlorobenzene 0.222 mg/L 0.225 mg/L ± 10% 99.8% 0.005 mg/L 0.075 mg/L N/A J-00077729
Tetrachloroethylene 0.015 mg/L 0.015 mg/L ± 10% 96.7% 0.0005 mg/L 0.005 mg/L N/A J-00082184
Toxaphene 0.015 mg/L 0.015 mg/L ± 10% 93.2% 0.001 mg/L 0.003 mg/L N/A J-00077730
2,4-D 0.218 mg/L 0.210 mg/L ± 10% 99.5% 0.0009 mg/L 0.07 mg/L N/A J-00085470
*Based on the use of Cryptosporidium parvum oocysts.
Tested and cerWL½ed by NSF International
against NSF/ANSI Standard 42 and
Standard 53 in model GE MWF for the
reduction of the claims speci½Hd on the
performance data sheet.