Installation Instructions

265 VOLT ELECTRICAL CONNECTION OPTIONS

WARNING:

Connection of this 265 V AC product to a branch circuit MUST be done by direct connection in accordance with the National Electrical Code. Plugging this unit into a building mounted exposed receptacle is not permitted by code.

These models must be installed using the appropriate GE power supply kit for the branch circuit amperage and the electrical resistance heater wattage desired.

Use the POWER CONNECTION CHART on page 16 to determine the correct kit required. One of the following installation methods (A or B) must be used.

A. FOR SUBBASE INSTALLATION

Electrical subbase kits are available to provide a flexible enclosure for direct connection.

Branch Circuit and

Proper GE

Power

Unit Amperage Rating

Subbase Kit

Supply Kit

 

 

 

 

15

RAK204E15

RAK5172

 

 

 

 

20

RAK204E20

RAK5202

 

 

 

 

30

RAK204E30

RAK5302

 

 

 

 

The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes.

B. FOR DIRECT CONNECT

INSTALLATION

If an electrical subbase is not used, direct connection to branch circuit wiring inside the provided junction box must be done in accordance with the following steps. Order the following Kit for 265-volt direct connection as required:

Branch Circuit and

Power

Unit Amperage Rating

Supply Kit

 

 

 

15

RAK5157

 

 

 

20

RAK5207

 

 

 

30

RAK5307

 

 

 

Proceed to the “MAKE ELECTRICAL CONNECTION TO THE UNIT” section.

NOTE: Order Kit RAK4002A to enable a quick disconnect inside the junction box.

14

Page 14
Image 14
GE 3900, 2900 Volt Electrical Connection Options, For Subbase Installation, For Direct Connect Installation