THE INSTALLATION SPACE

DIMENSIONS AND CLEARANCES

The finished

35-1/2"

Finished Width

Wall View

35"

25-3/8" Framed Models

25-3/4" Stainless Steel Models

Case Width

Case Depth

 

cutout width must be 35-1/2.

2-5/16"

THE INSTALLATION SPACE 6"

Electrical

10" Area

*83-1/2"

*84" From

Floor to

at

Top Frame

* Shipping height. The

refrigerator can be

adjusted to fit into a

cutout that is 83-1/2

min. to 84-1/2max.

height. Note that the top

84-1/2" max DIMENSIONS AND CLEARANCES 24" Cutout Depth

83-1/2" min

FinishedWater Supply

Opening 3-1/2"3-1/2"

5"Water And Electrical LocationsThe cutout depth must be 24″Cutout depth beneath a soffit:Additional Specifications5"

10"

3-1/2"

10"

75" From

Floor to Bottom

of Electrical Area

Rear

Product Clearances 36" Frame to Frame Width

Depth Including Handles:

26-7/8" Framed Models

case trim at the front is

1/2higher and will

overlap upper cabinetry

or soffit. Use leveling legs

and wheels for a

maximum 1height

adjustment.

Water And Electrical Locations

Electrical and water supply must be located as shown.

The cutout depth must be 24

The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation.

Cutout depth beneath a soffit:

When installed beneath a soffit, the soffit cannot exceed the 24installation depth shown. The top case trim overlaps the bottom of the soffit.

Additional Specifications

A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown.

Note: GFI (ground fault interrupter) is not recommended.

Water line can enter the opening through the floor or back wall. Route GE SmartConnectkit or 1/4O.D. copper tubing between the cold water line and the water connection location. The tubing should be long enough to extend to the front of the refrigerator. Installation of an easily accessible shut-off valve in the water line is required.

27-3/4" Stainless Steel Models

28-11/16" Professional Style Models

Product Clearances

These refrigerators are equipped with a 2-position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted.

Allow 25minimum clearance for a full 130° door swing. Allow 15for pan removal.

For a 90° door swing, allow 4min. clearance to a wall, for framed and stainless steel models. Allow 5min. clearance for professional style models. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted.

See illustrations pages 4 and 5 to determine door swing interaction with adjacent cabinets or countertops.

ZUG2, ZUGSS2 Unified Grille Panel Kit

If you are installing two refrigerators, side by side, the installation space must be 71-1/2wide.

Note: Additional cutout width may be required when side panels are used. Add side panel thickness to the finished cutout to calculate rough-in width.

The water and electrical locations for each product must be located as shown.

A separate 115V, 60Hz., 15 or 20 amp power supply is recommended for each product.

 

 

 

 

 

 

 

 

 

71-1/2" Finished Width

 

 

 

 

 

2-5/16"Electrical

 

 

 

 

 

 

 

 

 

24-3/16"

 

 

 

 

Wall View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10"

 

 

 

 

 

 

 

 

 

10"

 

 

 

 

 

 

 

 

 

 

 

 

 

84-1/2" max

 

 

 

24" Cutout Depth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75" From

83-1/2" min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Floor to Bottom

Finished

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-1/2"

3-1/2"

 

3-1/2"

3-1/2"

 

 

of Electrical Area

Opening

 

 

 

 

 

 

5"

 

 

 

 

 

 

 

 

 

5"

 

5"

 

 

 

 

 

 

 

 

 

 

 

 

5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10"

 

3-1/2"

 

 

10"

 

 

 

 

 

 

3-1/2" 10"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Supply

3

Page 3
Image 3
GE 49-60468-1 Design Guide, The Installation Space, Dimensions And Clearances, Water And Electrical Locations