4 3-Wire Power Cord Installation

Customer Service Troubleshooting Tips Installation Instructions Operating Instructions Safety Information

Installation of the range.

Read these instructions completely and carefully.

4 3-Wire Power Cord Installation

Do NOT remove ground strap connection.WARNING: The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the connector block. The power leads must be connected to the outside (brass colored) terminals.

Remove the 3 wire terminal screws from the connector block. Insert screws through each power cord terminal ring and into the connector block until the screws engage the nuts. Be certain that the center wire is connected to the center screw of the connector block. Tighten screws securely.

Do NOT remove ground strap connection.

Connector block

Neutral terminal

Ground strap

Power cord