BUILT-IN DISHWASHER

INSTALLATION INSTRUCTIONS

ALL ROUGH-IN PLUMBING AND ELECTRICAL MUST BE COMPLETED

BEFORE THE DISHWASHER IS PLACED IN THE UNDERCOUNTER OPENING

ALL ELECTRICAL AND PLUMBING WORK MUST BE IN ACCORDANCE WITH LOCAL CODES

DISHWASHER SHOULD NOT BE INSTALLED IN AREA WHERE FREEZING OF WATER MAY OCCUR

WARNING

TO REDUCE THE RISK OF ELECTRIC SHOCK, FIRE, OR INJURY TO PERSONS, THE INSTALLER MUST ENSURE THAT THE DISHWASHER IS COMPLETELY ENCLOSED AT THE TIME OF INSTALLATION.

MATERIALS YOU WILL NEED

Dishwasher

Materials required:

G 90¡ elbow

(3/8Ó NPT external thread on one end and opposite end sized to fit water supply)

G Thread seal tape G Wire nuts (2)

For new installations only:

G Waste tee for house plumbing, if applicable G Electrical cable or power cord, if applicable G Screw type hose clamps

G Strain relief for electrical connection G Hand shut-off valve (optional)

G Water line 3/8Ó min. copper or 1/2Ó min. plastic

Electrical Cable or

90° Elbow

Screw Type Clamps

Power Cord

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Strain Relief

Thread Seal Tape

Wire Nuts

Waste Tee

Hot Water Line

Wire Nuts

Safe

PREPARE DISHWASHER ENCLOSURE

(For Undersink Dishwasher - see page 26)

¥The touch cabinet opening must have a minimum width of 24Ó, and a minimum of 34Ó high from floor to underside of the countertop. Figure A

¥The back wall should be free of pipes or wires. Figure A

¥Adjacent cabinets should be square and plumb to ensure a good fit. Figure A

¥For corner installation, allow 2Ó min. clearance between dishwasher and adjacent cabinet or wall or other appliances. Figure B

Countertop

34-1/2"±1/4" Underside of Countertop to Floor

 

This Wall Area

 

 

 

 

must be Free of

 

 

 

Pipes or wires

 

24"

 

 

 

 

 

5"

4"

5"

Min.

 

4"

 

 

 

 

 

 

 

 

Plumbing and Electric Service

 

 

Must Enter Inside This Area

 

 

 

 

 

6"

Cabinets Square

 

 

 

and Plumb

 

24"

 

 

 

 

Min.

 

 

 

Installation

Dishwasher

Clearance for Door Opening 2" Minimum

 

 

 

 

 

¥ Make sure the floor is level inside the opening and even

 

 

 

 

 

with the finished floor of the kitchen.

 

 

 

 

 

¥ The dishwasher must be installed no more than 10 feet

 

 

 

 

 

from sink for proper drainage.

 

 

 

 

 

 

25"

 

 

¥ This dishwasher must be fully enclosed on the top, sides

 

 

 

 

 

and back.

 

 

 

 

 

 

 

 

 

 

¥ The dishwasher must not support any part of the

 

 

 

 

 

 

 

 

 

 

enclosure.

Instructions

15

Page 15
Image 15
GE 500A200P047 installation instructions BUILT-IN Dishwasher Installation Instructions, Materials YOU will Need

500A200P047 specifications

The GE 500A200P047 is a notable component within General Electric's extensive portfolio of innovative technologies. Widely recognized for its robust design and high performance, this device plays a pivotal role in various applications, particularly in industrial automation and power systems.

One of the standout features of the GE 500A200P047 is its exceptional reliability. Engineered for demanding environments, it is built to withstand extreme temperatures, vibrations, and other challenging conditions that are common in industrial settings. This reliability ensures that the component maintains optimal performance over time, reducing downtime and maintenance costs for operators.

The GE 500A200P047 also incorporates state-of-the-art technology aimed at enhancing efficiency and functionality. It features advanced digital controls, which allow for precise monitoring and management of electrical systems. This technological integration not only optimizes power distribution but also contributes to energy savings, making it an eco-friendly choice for enterprises looking to reduce their carbon footprint.

Furthermore, this component is designed with versatility in mind. It supports a range of applications, from low-voltage distributions to high-power industrial machinery. This adaptability makes the GE 500A200P047 a preferred choice among engineers and designers who require flexibility in their designs while ensuring top-tier performance.

Another notable characteristic of the GE 500A200P047 is its user-friendly interface. The design includes intuitive controls and diagnostic tools, facilitating easier operation and troubleshooting. This user-centric approach simplifies the complexity often associated with industrial systems, enabling quicker resolution of issues and enhancing overall productivity.

In terms of safety, the GE 500A200P047 is equipped with multiple safety features designed to protect both the system and its operators. These safety technologies prevent overload, short circuits, and other hazardous conditions, ensuring that operations run smoothly and securely.

In conclusion, the GE 500A200P047 stands out as a powerhouse in the industrial technology sector. With its impressive reliability, advanced digital controls, versatility, user-friendly interface, and robust safety features, it serves as a crucial component in modern industrial networks. Organizations looking to enhance efficiency and reliability in their operations will find the GE 500A200P047 to be an invaluable addition to their technological arsenal.