GE 500A200P047 Installation Instructions, Connect drain line, Drain Line Preparation, Figure Q

Models: 500A200P047

1 26
Download 26 pages 38.74 Kb
Page 20
Image 20
Step 12. Connect drain line

INSTALLATION INSTRUCTIONS

Step 12. Connect drain line

Follow all local codes and ordinances.

DRAIN LINE PREPARATION

1.All models are supplied with a pre-attached 78Ó long corrugated drain hose. The molded end is designed to fit 5/8Ó, 3/4Ó or 1Ó diameter connections to the waste tee or disposer. Cut on premarked line as required for your installation as illustrated in Figure Q.

Note: DO NOT CUT CORRUGATED PORTION OF HOSE.

 

Cut Lines

Do not cut corrugated

 

 

 

portion of hose

1"

3/4"

5/8"

 

Figure Q

If the location requires a longer drain hose, add up to 42Ó length to the factory installed hose. Use 5/8Ó inside diameter hose and thin wall copper coupler to join the hose ends. Secure connection with appropriate clamps (not supplied).

Note: TOTAL DRAIN HOSE LENGTH MUST NOT EXCEED 10 FEET FOR PROPER DRAIN OPERATION.

DRAIN LINE INSTALLATION

Connect drain line to waste tee or disposer as previously outlined in “Prepare Drain Plumbing” section of this manual. Refer to Figure S. Secure connection using appropriate clamps (not supplied).

Make sure drain hose is not kinked.

 

32"

 

 

18"

Min.

Fig. R

20"

 

Min.

 

 

Min.

 

 

 

Under the sink connection

Installation directly

Hose may be fastened to

through the floor

underside of countertop

 

IMPORTANT: TO PREVENT POSSIBLE DRAIN FROM SINK INTO DISHWASHER OR SIPHONING OF DISHWASHER WATER, DRAIN LINE MUST BE ROUTED AS FOLLOWS:

MIN. 30Ó ABOVE THE FLOOR FOR UNDER THE SINK CONNECTION.

MIN. 20Ó ABOVE THE FLOOR FOR INSTAL-LATION DIRECTLY THROUGH THE FLOOR.

20

Step 13. Connect power supply

Verify that power is turned off at source. If power cord is used, plug it into the wall outlet and go to Step 14.

If dishwasher is to be directly wired to house wiring, continue with this step.

Remove junction box cover.

Secure the power supply cable to the back of the junction box with a strain relief (not supplied). Connect incoming wires to dishwasher wires using wire nuts of appropriate size. Connect incoming white to white wire, black to black wire and incoming ground to green wire as shown in Figure S. Replace the junction box cover.

DRAIN LINE PREPARATION WARNING If house wiring is not 2-wire as shown in Figure S with a ground wire, a ground must be provided by

the installer.

When house wiring is aluminum, be sure to use UL/CSA. recognized anti-

oxidant compound and aluminum-to-copper connectors.

Figure Q WARNING Check to be sure that wiring is not pinched or in contact with the door springs.

NOTE: Check that harness

 

leads are threaded through

 

small hole in bracket.

Ground

White

 

Neutral

 

Black

Live

Figure S

Page 20
Image 20
GE 500A200P047 Installation Instructions, Connect drain line, Drain Line Preparation, Figure Q, Drain Line Installation