Power Panel and Replacement Parts (cont’d)

Standard Transition - 1600 to 3000 Amps

ARCH GRID ASSEMBLY

NN

CN

 

A4

SN

 

N1

N2

N3

 

SCR-N

DS

SCR-E

 

A3

SE

EN

CE

E1

E2

E3

 

 

STATIONARY CONTACT

 

 

MOVEABLE CONTACT

 

 

 

 

(ARCH GRID REMOVED FOR CLARITY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tag

Description

 

 

Recommended

 

Stock Numbers by Amperage

 

 

 

 

 

 

 

 

as Spares

1600

2000

 

3000

 

 

N 1,2,3, N

Cable Connection Lug

 

 

 

S1126F (2) Optional

S1126F (2) Optional

 

S1126F (2) Optional

 

 

E 1,2,3, N

 

 

 

 

 

 

 

 

 

 

 

Wire Size

 

 

 

(8) #2-600 MCM

(8) #2-600 MCM

 

(8) #2-600 MCM

 

 

T 1,2,3, N

 

 

 

 

 

 

 

Stationary Contact Assembly Kit

 

 

 

23P-1594

23P-1594

 

23P-1594

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Arc Grid Assembly Kit

 

 

 

23P-1171

23P-1171

 

23P-1171

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Movable Contact Assembly Kit

 

 

 

23P-1400

23P-1400

 

23P-1400

 

 

 

 

 

 

 

 

 

 

 

 

 

CN/CE

 

Coil Volts

Poles

*

 

 

 

 

 

 

 

 

120

2

 

 

SPO

SPO

 

SPO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240

2,3

 

 

K-2123F

K-2123F

 

K-2123F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

K-2127F

K-2127F

 

K-2127F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208

3

 

 

K-2125F

K-2125F

 

K-2125F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main Operating Coils

4

 

 

K-2128F

K-2128F

 

K-2128F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575/600

3

 

 

K-2153F

K-2153F

 

K-2153F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

K-2154F

K-2154F

 

K-2154F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

480

3

 

 

K-2120F

K-2120F

 

K-2120F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

K-2130F

K-2130F

 

K-2130F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

416

3

 

 

K-2126F

K-2126F

 

K-2126F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SN

CCN Cutout Switch

23P-1352

 

 

 

23P-1352

 

 

 

 

 

 

 

 

 

 

 

 

 

SE

CCE Cutout Switch

23P-1356

 

 

 

23P-1356

 

 

 

 

 

 

 

 

 

 

 

A3

Emergency Position Auxiliary Contact

(Qty 1) 23P-1356 (Qty 2) 23P-1357 (Qty 3) 23P-1353 (Qty 4) 23P-1355

 

 

 

 

 

 

 

 

 

A4

Normal Position Auxiliary Contact

(Qty 1) 23P-1352 (Qty 2) 23P-1353 (Qty 3) 23P-1357 (Qty 4) 23P-1359

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operator

 

 

 

 

 

 

 

 

DS

Disconnect Switch (older versions)

L-4009;

 

*

Operator L-4009; Contact Block L-1020

 

 

 

Contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block L-1020

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCR-N, SCR-E

SCR

 

 

*

PS-8896

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GE Zenith Controls

ZTG/ZTGD Operation and Maintenance Manual (70R-1000D)

29

Page 29
Image 29
GE 70R-1000D manual Standard Transition 1600 to 3000 Amps, Stationary Contact Moveable Contact