Installing the water heater.

Instructions Safety

Draining the Condensate

In certain conditions, installations in unconditioned space or having long horizontal or vertical runs may accumulate condensate.

In order to prevent condensate from draining back into the water heater installing a condensate trap and drain is recommended in a horizontal vent section as close as practical to the water heater vent connection.

Condensate is known to be acidic; refer to local, state (provincial) or federal codes for proper handling methods.

Installation

NOTICE: All pipe, fittings, solvent cement, primers and procedures must conform to American National Standards Institute and American Society for Testing and Materials (ANSI/ASTM) standards.

Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions

WARNING: DANGER OF FIRE OR BODILY INJURY - Solvent cements and primers are highly flammable. Provide adequate ventilation and do not assemble near heat source or open flame. Do not smoke. Avoid skin or eye contact. Observe all cautions and warnings on material containers.

CAUTION:

For proper installation:

DO NOT use solvent cement that has become curdled, lumpy or thickened.

DO NOT thin solvent cement. Observe shelf precautions printed on the containers.

For applications below 32°F use only low temperature type solvent cement.

Appropriate solvent and cleaner must be used for the type of vent pipe used (PVC, CPVC or ABS).

Cementing Joints

All joints in the vent piping must be properly sealed and the following materials are recommended:

PVC materials should use ASTM D-2564 grade cement.

CPVC materials should use ASTM F-493 grade cement.

ABS materials should use ASTM D-2235 grade cement.

Cleaner-Primer and Medium Body Solvent Cement:

Cut pipe end square, remove jagged edges and burrs. Chamfer end of pipe, then clean fitting socket and pipe joint area of all dirt, grease or moisture.

After checking pipe and socket for proper fit, wipe socket and pipe with cleaner-primer. Apply a liberal coat of primer to inside surface of socket and outside of pipe. Do not allow primer to dry before applying cement.

Apply a thin coat of cement evenly in the socket. Quickly apply a heavy coat of cement to the pipe end and insert pipe into fitting with a slight twisting motion until it bottoms out.

NOTICE: Cement must be fluid; if not, recoat.

Hold the pipe fitting for 30 seconds to prevent the tapered socket from pushing the pipe out of the fitting.

Wipe all excess cement from the joint with a rag. Allow 15 minutes before handling. Cure time will vary according to fit, temperature and humidity.

NOTICE: Stir the solvent cement frequently while using. Use a natural bristle brush or the dauber supplied with the can. The proper brush size is one inch.

NOTICE: This unit is equipped with a Flammable Vapor Sensor. Do not apply power until enough time has passed to allow the vapors from the primer and cement to dissipate.

16

Page 16
Image 16
GE AP13787 Draining the Condensate, Cementing Joints, Cleaner-Primer and Medium Body Solvent Cement

AP13787 specifications

The GE AP13787 is a smart and innovative appliance that has quickly gained attention for its advanced features and modern technologies. This product exemplifies GE's commitment to providing consumers with high-quality and efficient home solutions. The GE AP13787 stands out in the market, particularly due to its combination of functionality, energy efficiency, and user-friendly design.

One of the primary features of the GE AP13787 is its cutting-edge smart technology, which integrates seamlessly with smart home systems. This appliance is equipped with Wi-Fi connectivity, allowing users to control it remotely through a smartphone application. This capability enhances convenience, as consumers can monitor and adjust settings from anywhere, whether they are at home or on the go. The smart diagnosis feature also adds value, enabling users to troubleshoot potential issues quickly, minimizing downtime, and ensuring the appliance operates optimally.

In addition to its smart capabilities, the GE AP13787 boasts energy-efficient performance, an increasingly vital consideration for eco-conscious consumers. The appliance is designed to reduce energy consumption without sacrificing performance, helping users save on utility bills while also promoting sustainability. Its Energy Star certification is a testament to its efficiency, reflecting GE’s emphasis on responsible manufacturing and environmental stewardship.

Another notable characteristic of the GE AP13787 is its spacious and thoughtful design. It features ample storage and organization options, enabling users to maximize their kitchen space effectively. With adjustable shelves, clear bins, and easy-access compartments, finding and storing food items becomes a hassle-free experience.

Moreover, the GE AP13787 includes advanced cooling technologies that ensure optimal food preservation. Its Precision Temperature Management system keeps food at ideal temperatures, while the advanced air circulation technology promotes even cooling throughout the appliance. This feature is especially beneficial for maintaining the quality of perishables, extending their shelf life.

Overall, the GE AP13787 delivers a blend of modern technology, energy efficiency, and practical design. It is a perfect addition to any contemporary kitchen, catering to the demands of today’s consumers who seek convenience and quality. As the market for smart home appliances continues to grow, products like the GE AP13787 illustrate how innovation can enhance everyday living while being mindful of environmental impact.