Care and cleaning of the water heater.

Installation Instructions Safety

!DANGER: Combustible materials, such as clothing, cleaning materials, or flammable liquids, etc., must not be placed against or next to the water heater.

Housekeeping

Visually inspect pilot burner and relight if necessary.

To ensure sufficient ventilation and combustion air supply, proper clearances must be maintained.

When installed in a closet, DO NOT block or obstruct any of the combustion air inlet openings located around the perimeter of the water heater. A minimum of 1” is required between these combustion air inlet openings and any obstruction.

DO NOT obstruct or block the Flammable Vapor Sensor. The sensor does not require any maintenance or cleaning. DO NOT expose to cleaning agents.

Instructions

Venting System Inspection

Care and Cleaning Operating

The water heater’s internal flue must be inspected annually to be certain it is clean by removing the blower assembly and flue baffle.

When reinstalling the flue baffle make certain it is hung securely by its hanger at the top of the flue way.

Reinstall the blower assembly.

Inspect the gas venting system and the chimney.

Make certain the vent connector from the blower assembly to the chimney is properly positioned and securely attached.

If after inspection of the vent system you found soot or deterioration;

call the local gas utility to correct the problem and clean the flue, or replace the flue, flue baffle, and venting system before resuming operation of the water heater.

Test for spillage at the blower assembly relief opening after 5 minutes of burner operation. Use a flame of a match or candle or smoke.

Customer Service Troubleshooting Tips

Proper burner pattern.

Burner Inspection

Visually inspect the pilot burner and main burners annually.

Through the sight glass, inspect the pilot burner flame with the main burner off and inspect the main burner while firing.

If any unusual burner operation is noted, the water heater should be shut off until qualified service assistance can be obtained.

!CAUTION: For your safety, cleaning of the burner must be performed only by qualified service personnel, as it involves the disconnection of gas piping and leak testing.. The burner chamber is a sealed area. If the burner access door is removed, the burner access door gasket must be replaced.

For cleaning, remove the burner from the water heater. A vacuum cleaner can be used on the burner and floor shield inside the water heater.The burner can also be cleaned by scrubbing with mild detergent.

26

Page 26
Image 26
GE AP13787 Housekeeping, Venting System Inspection, Burner Inspection, Installation Instructions Safety

AP13787 specifications

The GE AP13787 is a smart and innovative appliance that has quickly gained attention for its advanced features and modern technologies. This product exemplifies GE's commitment to providing consumers with high-quality and efficient home solutions. The GE AP13787 stands out in the market, particularly due to its combination of functionality, energy efficiency, and user-friendly design.

One of the primary features of the GE AP13787 is its cutting-edge smart technology, which integrates seamlessly with smart home systems. This appliance is equipped with Wi-Fi connectivity, allowing users to control it remotely through a smartphone application. This capability enhances convenience, as consumers can monitor and adjust settings from anywhere, whether they are at home or on the go. The smart diagnosis feature also adds value, enabling users to troubleshoot potential issues quickly, minimizing downtime, and ensuring the appliance operates optimally.

In addition to its smart capabilities, the GE AP13787 boasts energy-efficient performance, an increasingly vital consideration for eco-conscious consumers. The appliance is designed to reduce energy consumption without sacrificing performance, helping users save on utility bills while also promoting sustainability. Its Energy Star certification is a testament to its efficiency, reflecting GE’s emphasis on responsible manufacturing and environmental stewardship.

Another notable characteristic of the GE AP13787 is its spacious and thoughtful design. It features ample storage and organization options, enabling users to maximize their kitchen space effectively. With adjustable shelves, clear bins, and easy-access compartments, finding and storing food items becomes a hassle-free experience.

Moreover, the GE AP13787 includes advanced cooling technologies that ensure optimal food preservation. Its Precision Temperature Management system keeps food at ideal temperatures, while the advanced air circulation technology promotes even cooling throughout the appliance. This feature is especially beneficial for maintaining the quality of perishables, extending their shelf life.

Overall, the GE AP13787 delivers a blend of modern technology, energy efficiency, and practical design. It is a perfect addition to any contemporary kitchen, catering to the demands of today’s consumers who seek convenience and quality. As the market for smart home appliances continues to grow, products like the GE AP13787 illustrate how innovation can enhance everyday living while being mindful of environmental impact.