GE CV936 Parts Provided, Duct Cover Requirements, Duct Cover Accessory, Installation Instructions

Models: CV936

1 24
Download 24 pages 20.77 Kb
Page 12
Image 12
PARTS PROVIDED

Installation Instructions

PARTS PROVIDED

Locate the hardware accessory box packed with the hood and check contents.

Screws, wall

fasteners, washers

2 Aluminum

Grease Filters

2 Control Knobs

Filter Support

Duct Transition

with Damper

DUCT COVER REQUIREMENTS

Review the following examples to ensure a trouble free installation using the duct cover accessory.

We recommend that the vent hood and decorative duct cover (if used) be on site before final framing and wall finishing. This will help to accurately locate studs, ductwork and electrical service. Read these instructions to determine if the duct cover accessory can be used for your installation situation.

Duct Cover Accessory:

Use the decorative duct cover to conceal duct work running from the

8 ft. ceilings: The hood must be installed at 30” above the cooking surface (or 66” above the floor). The duct cover willnot fit if the hood is installed at a lower or higher height. Use the outside 12” section, discard the inside section.

8 ft. Ceiling

12"

30"

top of the hood to the

 

 

 

 

 

 

 

 

 

 

 

ceiling.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The duct cover accessory

 

 

 

 

 

 

 

12"

 

consists of 2 pieces. The

 

 

 

 

 

 

 

 

 

 

 

outside piece is 12” high,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the inside piece is 22”.

 

 

 

 

 

 

 

 

 

 

 

 

 

22"

 

 

 

 

 

 

 

 

 

Nested together they are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12"

 

 

 

 

 

 

 

 

 

24” min., expanding to a

 

 

 

 

 

 

 

 

 

 

 

total maximum height of

 

 

 

 

 

 

 

 

 

 

 

34”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The outside piece can be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

used alone to fill a 12”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12"

 

 

 

 

 

height.

 

 

 

11"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• For heights over 12”, the ceiling bracket must be installed to secure the cover at the top.

To avoid unsightly gaps, plan the hood installation height for duct cover use.

The cover will fit a 12” min. height from the top of the hood to the ceiling,

– or 24” min. and expanding up to 34” from the top of the hood to the ceiling.

THE DUCT COVER CANNOT BE USED WHEN THE DISTANCE ABOVE THE TOP OF THE HOOD IS BETWEEN 12” AND 24”.

1 Ft = 0.3 m 1” = 2.5 cm

 

9 ft. Ceiling

30"

24"

 

24"30"

9 ft. ceilings: Install the hood 24” min. and up to a maximum of 30” above the cooking surface. The duct cover will expand to reach ceiling height.

 

10 ft. Ceiling

34"

30"

 

32"

36" Max.

 

10 ft. ceilings: nstall the hood 32” min. to 36” max. above the cooking surface. The duct cover will expand to a maximum of 34” above the top of the hood to meet the ceiling.

12

Page 12
Image 12
GE CV936 manual Parts Provided, Duct Cover Requirements, Duct Cover Accessory, Installation Instructions