GE GE 31-30263 05-10 $87,21, 35&$8&,Ï1, Prepare Dishwasher Enclosure, Installation Preparation

Models: GE 31-30263 05-10

1 24
Download 24 pages 34.35 Kb
Page 3
Image 3
PREPARE DISHWASHER ENCLOSURE

Installation Preparation

PREPARE DISHWASHER ENCLOSURE

‡7KHURXJKFDELQHWRSHQLQJPXVWEHDWOHDVWµGHHSDQG 5/8”To 24” Wide. The opening should beto 35”max. height.

‡7KHGLVKZDVKHUPXVWEHLQVWDOOHGVRWKDWGUDLQKRVHLV no more than 10feet in length for proper drainage.

‡7KHGLVKZDVKHUPXVWEHIXOO\HQFORVHGRQWKHWRS

32-1/2" to 35"

 

24"

 

Underside of

 

4" Min.

 

Countertop

 

 

 

 

to Floor

 

 

Cabinets

 

 

 

 

 

 

 

6"

Square

 

 

 

and

 

 

 

 

 

24

Min

 

Plumb

 

 

 

 

Floor MUST

 

 

 

Figure 1

be Even with

Plumbing and Electric Service

Room Floor.

 

Must Enter Shaded Area

 

 

&/($5$1&(6 When installed into a corner, allow 2” min. clearance between dishwasher and adjacent cabinet, wall or other appliances. Allow 25-5/8” min. clearance from the front of the dishwasher for door opening. Figure 2

Countertop

Dishwasher

25-5/8"

Clearance for Door Opening 2" Minimum

Figure 2

DRAIN REQUIREMENTS

Follow local codes and ordinances.

‡Do not exceed 10 feet distance to drain.

‡Do not connect drain lines from other devices to the dishwasher drain hose.

‡Dishwasher must be connected to waste line with an air gap (not supplied) or 32” minimum high drain loop, depending on local codes and ordinances to prevent back flow into the dishwasher .

‡Air gap must be used if waste tee or disposer connection is less than 18”above the floor to prevent siphoning.

DRAIN PREPARATION

The type of drain installation depends on answers to the following questions:

†Do local codes or ordinances require an air gap?

†Will waste tee or disposer connection be less than 18”above the floor?

†Will installation have a drain loop less than 32” above floor?

If the answer to ANY of the 3 questions above is YES, 0HWKRG0867EHXVHG. Otherwise either Method 1

or Method 2 may be used. Figure 3 or Figure 4.

DRAIN PREPARATION&$87,21

An air gap MUST BE USED if the drain hose is connected to waste tee or disposer lower than 18”above the floor. Failure to provide the proper drain connection height with air gap or 32” minimum, high drain loop will result in improper draining of the dishwasher.

&$87,2135(&$8&,Ï1

DEBE USARSE un espacio de aire si la manguera de drenaje se encuentra conectada a una T de eliminación o desecho inferior a 18” sobre el piso. No brindar la adecuada altura de conexión de drenaje con un espacio de aire o un circuito de desagüe de 32” como mínimo, provocará un drenaje inadecuado del lavaplatos.

Method 1 Air Gap with Waste Tee or Disposer

Figure 3

Method 2 High Drain with Waste Tee or Disposer

Provide a method to attach drain hose to underside of countertop.

 

 

32"

18""

32"

Min.

Min.

18"

Minin..

 

Min.

 

 

Figure 4

Install waste tee or disposer and air gap according to Manufacturer s instructions.

CABINET PREPARATION

‡Drill a 1-1/2” dia. hole in the cabinet wall within the shaded areas shown in Figure 1 for the drain hose connection. The hole should be smooth with no sharp edges.

3

Page 3
Image 3