PREPARE ELECTRICAL WIRING

Installation Preparation

PREPARE ELECTRICAL WIRING

WARNING

)253(5621$/6$)(7<5HPRYHKRXVH fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance.

ADVERTENCIA PARA SEGURIDAD ADVERTENCIA

ADVERTENCIA PARA SEGURIDAD

3(5621$/4XLWHHOIXVLEOHRDEUDHO interruptor de circuitos antes de comenzar la instalación. No utilice un cable de extensión o un enchufe adaptador con este artefacto.

Electrical Requirements

‡7KLVDSSOLDQFHPXVWEHVXSSOLHGZLWK9+]DQG connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. ‡:LULQJPXVWEHZLUHZLWKJURXQG ‡,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH requirements, call a licensed electrician before proceeding.

*URXQGLQJ,QVWUXFWLRQV³&DEOH'LUHFW

This appliance must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal or lead on the appliance.

*URXQGLQJ,QVWUXFWLRQV³3RZHU&RUG0RGHOV This appliance must be grounded. In the event of a

malfunction or breakdown, grounding will reduce the risk of electrical shock by providing a path of least resistance for electric current. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with local codes and ordinances.

WARNING

The improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt that the appliance is properly grounded.

ADVERTENCIA

/DFRQH[LyQLQDGHFXDGDGHOFRQGXFWRUGH conexión a tierra del equipamiento puede provocar un riesgo de descarga eléctrica. Consulte a un electricista calificado o representante de servicio técnico si tiene dudas sobre la correcta conexión a tierra del aparato.

1-1/2" Dia.

Hole (Max.)

3" from

Cabinet

24" from Wall

 

Ground

 

Figure 5

Black

White

 

 

 

Cabinet Preparation & Wire Routing

‡The wiring may enter the opening from either side, rear or the floor within the shaded area.

‡Cut a 1-1/2” max. dia. hole to admit the electrical cable. The hole must be free of sharp edges. If the cabinet wall is metal, the hole edge must be covered with a bushing.

‡Cable direct connections may pass through the same hole as the drain hose and hot water line, if convenient. If cabinet wall is metal, the hole edge must be covered with a bushing.

127( Power cords with plug must pass through a separate hole.

Electrical Connection to Dishwasher

Electrical connection is on the right front of dishwasher . ‡For cable direct connections the cable must be routed as shown in Figure 5. Cable must extend a minimum of 24”from the rear wall.

‡For power cord connections, install a 3-prong grounding type receptacle. The power-supply receptacle for the appliance shall be installed in a cabinet or on a wall adjacent to the undercounter space in which the appliance is to be installed.