IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.

WHEN USING YOUR APPLIANCE

Use this appliance only for its intended purpose as described in this Owner’s Manual.

„Do not mix chlorine bleach with ammonia or acids such as vinegar and/or rust remover. Mixing different chemicals can produce a toxic gas which may cause death.

„Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled, or has missing or broken parts, including a damaged cord or plug.

„Never reach into the appliance while it is moving. Before loading, unloading or adding clothes, wait until the machine has completely stopped.

„Clean the lint filter before each load to prevent lint accumulation inside the dryer or in the room. DO NOT

OPERATE THE DRYER WITHOUT THE LINT FILTER IN PLACE.

„Do not wash or dry articles that have been cleaned in, washed in, soaked in or spotted with combustible or explosive substances (such as wax, oil, paint, gasoline, degreasers, dry-cleaning solvents, kerosene, etc.). These substances give off vapors that may ignite or explode. Do not add these substances to the wash water. Do not use or place these substances around your appliance during operation.

„Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a clothes load to catch fire.

„Any article on which you have used a cleaning solvent or that contains flammable materials (such as cleaning cloths, mops, towels used in beauty salons, restaurants or barber shops, etc.) must not be placed in or near the appliance until solvents or flammable materials have been removed. There are many highly flammable items used in homes such as acetone, denatured alcohol, gasoline, kerosene, some household cleaners, some spot removers, turpentines, waxes, wax removers and products containing petroleum distillates.

„The laundry process can reduce the flame retardancy of fabrics. To avoid such a result, carefully follow the garment manufacturer’s care instructions.

„Do not dry articles containing rubber, plastic or similar materials such as padded bras, tennis shoes, galoshes, bath mats, rugs, bibs, baby pants, plastic bags, pillows, etc. that may melt or burn. Some rubber materials, when heated, can under certain circumstances produce fire by spontaneous combustion.

„Do not store plastic, paper or clothing that may burn or melt on top of the dryer during operation.

„Garments labeled Dry Away from Heat or Do Not Tumble Dry (such as life jackets containing Kapok) must not be put in your dryer.

„Do not dry fiberglass articles in your dryer. Skin irritation could result from the remaining particles that may be picked up by clothing during subsequent dryer uses.

„To minimize the possibility of electric shock, unplug this appliance from the power supply or disconnect the appliance at the household distribution panel by removing the fuse or switching off the circuit breaker before attempting any maintenance or cleaning (except the removal and cleaning of the lint filter). NOTE: Turning the Cycle Selector knob to an off position or pressing PAUSE does NOT disconnect the appliance from the power supply.

„The interior of the machine and the exhaust duct connection inside the dryer should be cleaned at least once a year by a qualified technician. See the Loading and Using the Dryer section.

„If yours is a gas dryer, it is equipped with an automatic electric ignition and does not have a pilot light. DO NOT ATTEMPT TO LIGHT WITH A MATCH. Burns may result from having your hand in the vicinity of the burner when the automatic ignition turns on.

„You may wish to soften your laundered fabrics or reduce the static electricity in them by using a dryer- applied fabric softener or an anti-static conditioner. We recommend you use either a fabric softener in the wash cycle, according to the manufacturer’s instructions for those products, or try a dryer-added product for which the manufacturer gives written assurance on the package that their product can be safely used in your dryer. Service or performance problems caused by use of these products are the responsibility of the manufacturers of those products and are not covered under the warranty to this appliance.

„Do not spray any type of aerosol into, on, or near dryer at any time. Do not use any type of spray cleaner when cleaning dryer interior. Hazardous fumes or electrical shock could occur.

4

Page 4
Image 4
GE GUAP270, GTUP240, GUAP240, GTUN275, GTUP270 When Using Your Appliance, Operate the Dryer Without the Lint Filter in Place

GUAP270, GUAP240, GTUN275, GTUP240, GTUP270 specifications

The GE GTUP270, GTUP240, GTUN275, GUAP240, and GUAP270 are advanced gas turbine models designed and manufactured by General Electric (GE) to meet the rigorous demands of today's power generation market. These turbines are known for their efficiency, reliability, and innovative engineering, addressing the needs of both utility and industrial applications.

The GTUP270 is a robust unit that combines high efficiency with low emissions, making it suitable for both base load and peaking power generation. It features a modular design, allowing for easy maintenance and reduced downtime. The turbine utilizes advanced materials and cooling technologies to withstand high operational temperatures, achieving superior performance under varying load conditions.

The GTUP240 is slightly smaller yet equally efficient, designed for quick-start applications. Its compact footprint and lightweight design make it an attractive option for locations with space constraints. The GTUP240 leverages digital controls and predictive maintenance tools to optimize performance and minimize operational costs, reflecting GE's commitment to integrating cutting-edge technology into its products.

The GTUN275 expands the range of GE's offering, providing a flexible solution for combined cycle plants. This turbine is optimized for fuel efficiency and equipped with advanced aerodynamic designs, allowing it to operate at high pressure ratios. Its ability to deliver enhanced operational flexibility makes it ideal for balancing renewable energy sources and managing grid stability.

The GUAP240 is specifically designed for industrial applications, boasting rugged construction to handle harsh operating environments. With a focus on fuel flexibility, this turbine can utilize various fuels, including natural gas and liquid fuels, ensuring continuous operation in different scenarios. Its enhanced heat recovery capabilities allow for improved overall plant efficiency.

The GUAP270 is a larger variant, providing increased power output without sacrificing efficiency. It incorporates GE's latest technologies in cooling and combustion systems, resulting in lower emissions and reduced environmental impact. This model is also designed for easy integration into existing power plants, providing a cost-effective solution for operators looking to upgrade their facilities.

In summary, the GE GTUP270, GTUP240, GTUN275, GUAP240, and GUAP270 represent the pinnacle of gas turbine technology, offering a range of features that cater to different operational needs. With an emphasis on efficiency, flexibility, and low emissions, these turbines are engineered to support a sustainable energy future while ensuring maximum uptime and reliability for power generation facilities.