GE GX1S15C, GX1S04C Mounting Bracket to Cabinet Wall, Tubing Connections-CompressionStyle, A B C

Models: GN1S04C GX1S15C GX1S04C

1 36
Download 36 pages 7.53 Kb
Page 7
Image 7
Mounting Bracket to Cabinet Wall

Mounting Bracket to Cabinet Wall

The bracket can be used as a template for marking the location of the mounting screws. When determining the location of the bracket make sure you leave 1-1⁄2″ to 2″ of free area under the sumps to allow for sump removal and enough space on either side to make the tubing connections.

Tubing Connections—Compression Style

(Models GX1S04C and GN1S04C)

1 Run the length of 3⁄8″ tubing, connected to the bottom of faucet, to the filter system outlet. Allow enough slack in the tubing so the unit can be easily removed for filter changes. Measure and cut the end of the tubing square.

2 Slide a compression nut onto the end of the tubing and push a tubing insert into the tubing.

3 Connect the tubing and tighten the compression nuts securely.

4 Repeat the preceding steps to connect a length of tubing between the filter system inlet and the water supply/saddle valve (illustration in the Installation Overview section).

2-3⁄4

 

 

Tubing connector

 

(outlet)

Mounting

 

bracket

 

Tubing connector

Mounting

(inlet)

screws

Sump

 

Tubing Connections—Compression Style 1 -1⁄2 to 2

Tubing Connections—Push-In Style (Model GX1S15C)

1 Run the length of the 3⁄8″ tubing, connected to the bottom of the faucet, to the filter system outlet (illustration above). Allow enough slack in the tubing so that the unit can be easily removed.

2 Measure and cut the end of the tubing square using a sharp cutter or knife. Remove any burrs (illustration A).

3 Inspect the end of the tubing, about 1 inch, to be sure there are no imperfections. It may be necessary to cut the tubing again.

4 Mark the tubing for length of insertion. For 3/8″ OD tubing the insertion length should be approximately 3/4 of an inch. Tubing must be fully inserted to avoid leaks.

5 DO NOT REMOVE GRAY COLLET. Push the tubing all the way into the fitting until it bottoms out. The insertion line should be hidden or barely visible (illustration B and C). Slightly pull on the tubing to verify engagement.

6 Repeat the procedure to connect the tubing between the filter system inlet and the water supply/saddle valve (illustration in the Installation Overview section).

7 To remove tubing (illustration D), depress and hold gray collet. Pull tubing to remove.

NOTE: Avoid installing the unit where the tubing is pulled at a sharp angle. This type of installation may cause the fittings to leak. If using tubing other than what is supplied, be sure it is high quality, exact size and roundness, and has a smooth surface.

A

B

C

Cut tubing square

End of tubing round and smooth, with no cuts,

nicks or flat spots (approximately 1)

Gray Collet

(DO NOT REMOVE)

Insertion line

Tubing

 

3⁄4

Tubing must

 

be fully inserted

 

 

Insert

 

to avoid leaks.

Gray Collet

 

 

(DO NOT

 

 

REMOVE)

 

 

Insertion line

3 4"

 

Insert tubing (Models GX1S04C and GN1S04C)

Tubing Connections—Push-In Style (Model GX1S15C) EngagementA

3/4(3/8tubing)

D

Gray Collet

Tubing

Depress gray collet

 

and pull tubing

 

to remove

7

Page 7
Image 7
GE GX1S15C Mounting Bracket to Cabinet Wall, Tubing Connections-CompressionStyle, Models GX1S04C and GN1S04C, A B C