GE GN1S04C Feed Water Supply, For 1/2 OD or larger metal tubing only, A. Preferred Installation

Models: GN1S04C GX1S15C GX1S04C

1 36
Download 36 pages 7.53 Kb
Page 5
Image 5
Feed Water Supply

Feed Water Supply

Check and comply with local plumbing codes as you plan,

then install a cold feed water supply fitting. For new home installation using standard plumbing fittings, see first two illustrations below. A typical installation for existing homes using the saddle valve is shown in third illustration below.

A. PREFERRED INSTALLATION

1 Turn off the cold water supply.

2 Complying with plumbing codes, install a fitting on the cold water pipe to adapt 3⁄8″ OD tubing. A typical connection is shown in illustrations at right (parts not included). Make sure a water supply valve is used.

Typical location

Cold water

Preferred water supply connection (using compression fitting)

Water supply valve

Insert (not included)

Ferrule

Cold water A. PREFERRED INSTALLATION pipe

3⁄8tubing to inlet

B. OPTIONAL HOME INSTALLATION Where codes permit

*For 1/2" OD or larger metal tubing only.

NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of the saddle valve. For installation,

use plumbing code 248-CMR of the Commonwealth of Massachusetts.

1

Turn off the cold water supply and attach saddle valve as shown in

illustration at right.

 

 

DANGER: To protect yourself from serious injury or fatal shock, use

 

a battery-powered hand drill only to make the hole. DO NOT USE AN

 

ELECTRIC DRILL.

 

Close the water supply valve by turning the handle clockwise.

2

 

Open the main water supply valve and several house faucets to purge

3

air from the system. Close faucets when water runs smoothly.

 

Snug valve into bracket

DO NOT OVERTIGHTEN

Some threads B. OPTIONAL HOME INSTALLATION Where codes permit should be visible *For 1/2" OD or larger metal tubing only.ELECTRIC DRILL.

Rubber gasket

Optional water supply connection (using saddle valve)*

*For 1/2" OD or larger metal tubing only.

Nut (2)—not

 

 

required if holes

Pre-drill

 

in clamp are

1⁄4hole

Seal—make sure the

threaded

 

 

seal is in place

 

 

 

 

Clamp X

Clamp Z

 

Valve

 

 

Washer

Tubing adapter Manual background

Handle

Compression nut Manual background

Use to connect the tubing

5

Page 5
Image 5