WARNING! INSTALLATION SAFETY INSTRUCTIONS

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, manufacturer (dealer) or the gas supplier.

Safety Instructions

Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use NEW flexible connectors when installing a gas appliance.

IMPORTANT: Remove all packing material and literature from oven before connecting gas and electrical supply to range.

Have your range installed by a qualified installer.

Your range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition).

Before installing your range on linoleum or any other synthetic floor covering, make sure the floor covering can withstand 180°F without shrinking, warping or discoloring.

Do not install the range over carpeting unless a sheet of 1/4″ thick plywood or similar insulator is placed between the range and carpeting.

Make sure the wall coverings around the range can withstand heat generated by the range up to 200°F.

Avoid placing cabinets above the range. To reduce the hazard caused by reaching over the open flames of operating burners,

install a ventilation hood over the range that projects forward at least 5″ beyond the front of the cabinets.

The ventilating hood must be constructed of sheet metal not less than 0.0122″ thick.

Install above the cooktop with a clearance of not less than 1/4″ between the hood and the underside of the combustible material or metal cabinet. The hood must be at least as wide as the appliance and centered over the appliance. Clearance between the cooking surface and the ventilation hood surface

MUST NEVER BE LESS THAN 24 INCHES.

EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.

If cabinets are placed above the range, allow a minimum clearance of 30″ between the cooking surface and the bottom of unprotected cabinets.

If a 30″ clearance between cooking surface and overhead combustible material or metal cabinets cannot be maintained, protect the

underside of the cabinets above the cooktop with not less than 1/4″ insulating millboard

covered with sheet metal not less than 0.0122″ thick.

Clearance between the cooking surface and protected cabinets MUST NEVER BE LESS THAN 24 INCHES. The vertical distance from the plane of the cooking surface to

the bottom of adjacent overhead cabinets extending closer than 1″ to the plane of the range sides must not be less than 18″. (See the Dimensions and Clearances illustration in this section.)

CAUTION: Items of interest to children should not be stored in cabinets above a range or on the backsplash of a range—children climbing on the range to reach items could be seriously injured.

Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support

39

Page 39
Image 39
GE J2B915 installation instructions Must Never be Less than 24 Inches

J2B915 specifications

The GE J2B915 is an advanced gas turbine engine that represents a significant milestone in aerospace technology, primarily designed for use in regional and business aircraft. Engineered by General Electric, the J2B915 combines innovative design features with state-of-the-art technologies to provide high performance, reliability, and efficiency.

At the heart of the J2B915 is its powerful core, which is designed to operate at high temperatures and pressures. This capability allows the engine to deliver substantial thrust while maintaining a relatively low fuel consumption rate. The engine achieves this efficiency through its advanced compressor and turbine design. The axial-flow compressor, known for its ability to compress air efficiently, contributes to the overall performance of the engine, while the high-pressure turbine extracts energy effectively to drive the compressor.

One of the standout features of the J2B915 is its noise reduction technology. In an era where environmental regulations are becoming increasingly stringent, the engine's design incorporates features aimed at minimizing noise footprint during operation. This is achieved through the use of advanced acoustic materials and innovative turbine blade designs, which work together to reduce noise levels while ensuring optimal performance.

Another key characteristic of the J2B915 is its modular design, which enhances maintainability and serviceability. This modularity allows for easier access to engine components, simplifying routine inspections and repairs. The design philosophy also translates to a reduction in downtime, which is critical for commercial operators seeking to maximize aircraft availability.

The GE J2B915 also boasts impressive durability and reliability. Engineered with advanced materials and coatings, it is capable of withstanding the rigors of continuous operation in various environments. The engine’s reliability is bolstered by GE’s rigorous testing protocols and quality assurance processes, ensuring that it meets the high standards expected by operators worldwide.

In terms of controls and monitoring, the J2B915 utilizes an advanced digital engine control system. This system monitors various performance parameters in real-time, allowing for precise management of engine functions and enhancing operational efficiency. The digital technology also supports predictive maintenance, alerting operators to potential issues before they escalate into more significant problems.

In conclusion, the GE J2B915 gas turbine engine embodies a blend of cutting-edge technologies, robust design, and a commitment to performance. Its high efficiency, low noise output, and reliable operation make it a preferred choice for regional and business aviation markets, cementing its reputation in the competitive landscape of aerospace propulsion systems.