!!J?
WARNING: CONNECTORBLOCK IS
APPROVED FOR COPPER WIRE
.~CONNECTIONONLY.
1
““’2. Aluminum Wiring
A. Connect length ofcopper building wire to
range terminal block.
B. Splicecopper wires to aluminum wiring using
special connectors designed and U.L.approved for
joining copper to aluminum, and followthe
connector manufacturer’s recommended
procedure closely.
NOTE: Wire used, location and enclosure of
splices, etc., must conform to good wiring practice
and local codes.
STEP 5
WIRE SYSTEM
SPECIAL GROUNDING INSTRUCTIONS
WARNING:
Frame grounded to neutral ofappliance through a
link. Ifused in aMOBILE HOME or if LOCAL
CODES do not permit grounding through the
neutral:
1) disconnect the link from neutral,
2) use grounding terminal or lead to ground unit in
accordance with local codes, and
3) connect neutral terminal or lead to branch
circuit in usual manner.
(Ifthe appliance is to be connected by means of a
cord set, use 4-conductor cord forthis purpose.)
/
CONNECTOR
BLOCK
4TH GROUNDING LEAD ~~ \GROUND
LUG
STEP 6
ANTI-TIP BRACKET INSTALLATION
AN ANTI-TIPbracket is supplied with instructions
for installation in avariety oflocations. The
instructions include atemplate, aparts list and a
list oftools necessary to complete the installation.
]Read the IMPORTANTSAFETYINSTRUCTIONS
and the instructions that fityour situation before
beginning installation.
WARNING
1. Rangemust be secured by ANTI-TIPbracket
supplied.
2. See instructions to install (supplied with
bracket).
3. Unless properly installed, range could be tipped
by stepping or sitting on door. Injury might result
fi-omspilled hot liquids or from range itself.
Typicalinstallation of Anti-Tip bracket
Attachment to Wall
Bracket
\
Screw Must Enter I
Wood orMetal “x
STEP 7
LEVELING THE RANGE
The range must be leveled. Leveling feet are
located on each corner ofthe base of the range.
Removethe storage drawer and rotate the leveling
feet in or out as required. To remove drawer, pull it
out allthe way, tilt up the front and remove it.To
replace, insert glides at back ofdrawer beyond
stop on range glides. Liftdrawer if necessary to
insert easily.
One ofthe rear leveling feet will engage the ANTI-
TIP bracket (allowfor some side to side
adjustment). Allowaminimum clearance of 1/8”
between the range and the leveling footthat is to
be installed into the ANTI-TIPbracket.
Check the range for proper installation into the
ANTI-TIPbracket (after the range has been
properly installed) by grasping the edges ofthe
REARburner holes and carefully attempting to tilt
the range forward.
STEP 8
FINAL CHECK
Be sure allswitches are in the “off” position before
leaving the range.
27