Installation Instructions
A
Cutout for 27″ (68.6 cm) Single Built-In Ovens only
Under Counter
Electric cooktops may be installed over this oven. See cooktop installation instructions for cutout size. See label on top of oven for approved cooktop models.
240V / 208V |
| |
Junction Box |
| |
Location (junction | Electrical connections for | |
box may be in | ||
cooktop must be located in | ||
adjacent cabinet) | ||
an adjacent accessible | ||
|
63.5 cm (25”)
Top and/or side fillers may be necessary
19.7 cm (7 3/4”) | location to the right. | |
| ||
| Max. |
|
|
|
|
if unit is positioned between existing cabinets. Be sure they are attached securely, since they will anchor the oven in the cabinet.
1.9cm (3/4”)
Support Platform
Required
63.5cm
(25”) Min.
64.1cm
(25 1/4”) Max.
70.2cm
(27 5/8”) Min.
71.4 cm
(28 1/8”) Max.
Allow 2.5 cm (1”) overlap top of oven,
2.5cm (1”) overlap side edges of cutout and 2.5 cm (1”) overlap bottom of cutout
Must match toekick height
55.9cm (22”)
Min. Above Support Platform
61 cm (24”)
10.2 cm (4”)
Typical
Toekick
91.4cm (36”)
Typical Countertop Height
MUST SUPPORT 68 Kg (150 LBS.)
NOTE: This oven is only approved to be installed under the specific models as labeled on this unit.