DUCTWORK CALCULATIONS

Installation Instructions

DUCTWORK CALCULATIONS

Calculate Total Equivalent Ductwork Length

 

Equivalent

Number

Equivalent

Duct Pieces

Length* x

Used =

Length

5round

 

 

 

 

 

straight

2.7 ft.

x

(

ft.)=

ft.

6round

 

 

 

 

 

straight

1 ft.

x

(

ft.)=

ft.

314x 10

 

 

 

 

 

straight

1 ft.

x

(

ft.)=

ft.

5, 90°

 

 

 

 

 

elbow

37 ft.

x

(

) =

ft.

6, 90°

 

 

 

 

 

elbow

12 ft.

x

(

) =

ft.

5, 45°

 

 

 

 

 

elbow

18 ft.

x

(

) =

ft.

6, 45°

 

 

 

 

 

elbow

7 ft.

x

(

) =

ft.

Flexible

 

 

 

 

 

metal offset

See Calculations in

 

adapter

Step 5A.

 

 

 

ft.

314x 10

 

 

 

 

 

90° elbow

14 ft.

x

(

) =

ft.

314x 10

 

 

 

 

 

45° elbow

8 ft.

x

(

) =

ft.

314x 10

 

 

 

 

 

90° flat elbow

33 ft.

x

(

) =

ft.

5round

 

 

 

 

 

to 314x 10

 

 

 

 

 

transition

3 ft.

x

(

) =

ft.

6round

 

 

 

 

 

to 314x 10

 

 

 

 

 

transition

2 ft.

x

(

) =

ft.

 

Subtotal Column 1 =

ft.

*Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any downdraft cooktop.

†Measure and list feet of straight duct used. Count and list the quantity of all other duct pieces for the “Number Used” of each type.

IMPORTANT:

For maximum efficiency, use the shortest and straightest duct run possible, with as few fittings as possible. For satisfactory performance, the duct run should not exceed 100 feet equivalent length.

Venting performance is improved by using larger diameter duct.

 

Equivalent

Number

Equivalent

Duct Pieces

Length* x

Used

=

Length

5round

 

 

 

 

 

to 314x 10

 

 

 

 

 

transition

 

 

 

 

 

90° elbow

37 ft.

x

(

) =

ft.

6round

 

 

 

 

 

to 314x 10

 

 

 

 

 

transition

 

 

 

 

 

90° elbow

4 ft.

x

(

) =

ft.

314x 10

 

 

 

 

 

to 6round

 

 

 

 

 

transition

2 ft.

x

(

) =

ft.

314x 10

 

 

 

 

 

to 6round

 

 

 

 

 

transition

 

 

 

 

 

90° elbow

4 ft.

x

(

) =

ft.

Tapered 5

 

 

 

 

 

round to

 

 

 

 

 

6round

 

 

 

 

 

transition

6 ft.

x

(

) =

ft.

5round collar

 

 

 

 

 

to 6round

 

 

 

 

 

transition

13 ft.

x

(

) =

ft.

5round

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

84 ft.

x

(

) =

ft.

6round

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

24 ft.

x

(

) =

ft.

314x 10

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

24 ft.

x

(

) =

ft.

6round

 

 

 

 

 

roof cap

33 ft.

x

(

) =

ft.

 

Subtotal Column 2 =

ft.

 

Subtotal Column 1 =

ft.

 

TOTAL DUCTWORK =

ft.

Should not exceed 100 feet.

If flexible metal ducting is used, all the equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible.

DO NOT use flexible plastic ducting.

Vent installation should not exceed 100 feet equivalent length.

Blower is rated at 400 CFM at 0.1 inch of water back pressure.

18