![Electrical Connections cont.](/images/new-backgrounds/80975/8097515x1.webp)
Installation Instructions
Electrical Connections cont.
3POWER CORD AND STRAIN RELIEF INSTALLATION
A Remove the wire cover |
|
(on the back of the |
|
range) by removing 2 |
|
screws, using a 1/4″ |
|
nut driver. | Wire |
Do not discard these | Cover |
|
screws.
B Remove the knockout ring
Terminal block (appearance may vary)
Knockout
Knockout ringring removed in bracket
C For power cord installations only (see
the next step if using conduit), assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal block. If tabs are present at the end of the winged strain relief, they can be removed for better fit.
NOTE: Do not install the power cord without a strain relief. The strain relief bracket should be installed before reinstalling the rear range wiring cover.
Terminal block
Strain relief
Power cord
Bracket
D For conduit installations only,
purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block.
NOTE: Do not install the conduit without a squeeze connector. The squeeze connector should be installed before reinstalling the rear range wiring cover.
Terminal block
Squeeze connector
Conduit | Bracket |
|
8