Electrical Connections cont.

Installation Instructions

Electrical Connections cont.

3POWER CORD AND STRAIN RELIEF INSTALLATION

A Remove the wire cover

 

(on the back of the

 

range) by removing 2

 

screws, using a 1/4

 

nut driver.

Wire

Do not discard these

Cover

 

screws.

B Remove the knockout ring (1-3/8) located on bracket directly below the terminal block. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed.

Terminal block (appearance may vary)

Knockout

Knockout ringring removed in bracket

C For power cord installations only (see

the next step if using conduit), assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal block. If tabs are present at the end of the winged strain relief, they can be removed for better fit.

NOTE: Do not install the power cord without a strain relief. The strain relief bracket should be installed before reinstalling the rear range wiring cover.

Terminal block

Strain relief

Power cord 3POWER CORD AND STRAIN RELIEF INSTALLATION

Bracket

D For conduit installations only,

purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block.

NOTE: Do not install the conduit without a squeeze connector. The squeeze connector should be installed before reinstalling the rear range wiring cover.

Terminal Do not discard these block

Squeeze connector

Conduit

Bracket

 