Installation Instructions
8REMOVE DUCT KNOCKOUT(S)
If recirculating,
recirculated configuration for JV6 Series models.
Using a flat blade screwdriver, remove the appropriate duct knockout(s) from the top or back of the hood.
10FOR 31⁄4″ X 10″ RECTANGULAR
DUCTED DISCHARGE
INSTALLATIONS ONLY:
Attach exhaust adaptor/damper over knockout opening with two exhaust adaptor screws. Make sure damper pivot is nearest to top/back edge of hood. Remove tape from damper flap.
31⁄4″ x 10″ Rectangular vertical discharge. Remove top rectangular duct knockout only.
7″ Round vertical discharge. Remove semi- circular duct knockout and top rectangular duct knockout.
31⁄4″ x 10″ Rectangular horizontal discharge. Remove rear rectangular duct knockout only.
Up to 1″ | Tape |
side adjustment |
|
Pivot | Top/back edge |
| |
| Exhaust adaptor/damper |
| (vertical discharge position |
| shown) |
NOTE: The exhaust adaptor/damper can be installed up to 1 inch on either side of the hood center to accommodate
NOTE: If the hood is to be installed in a recirculating,
be ordered from your GE supplier. Skip to Step 12 D and proceed.
9FOR HORIZONTAL DISCHARGE
INSTALLATIONS ONLY:
Remove the plate (on models so equipped) in front of the horizontal discharge knockout. Cut the ties, lift plate out, and discard plate. DO NOT REMOVE the metal strip held in place with two screws.
Metal strip | Ties |
Screw
Plate
12
11FOR 7″ ROUND VERTICAL
DUCTED DISCHARGE
INSTALLATIONS ONLY:
7″ round exhaust adaptor
NOTE: The 7″ round exhaust adaptor can be installed up to 1 inch on either side of the hood center to accommodate