1 PROVIDE ADEQUATE GAS SUPPLY
Your range is designed to operate at a pressure of 4″ of water column on natural gas or, if designed for LP gas (propane or butane), 10″ of water column. Make sure you are supplying your range with the type of gas for which it is designed. This range is convertible for use on natural or propane gas. If you decide to use this range on LP gas, conversion must be made by a qualified LP installer before attempting to operate the range on that gas.
For proper operation, the pressure of natural gas supplied to the regulator must be between 4″ and 13″ of water column. For LP gas, the pressure supplied must be between 10″ and 13″ of water column. When checking for proper operation of the regulator, the inlet pressure must be at least 1″ greater than the operating (manifold) pressure as given above. The pressure regulator located at the inlet of the range manifold must remain in the supply line regardless of whether natural or LP gas is being used. A flexible metal appliance connector used to connect the range to the gas supply line should have an I.D. of 1/2″ and be
5 feet in length for ease of installation. In Canada, flexible connectors must be single wall metal connectors no longer than 6 feet in length.
2 CONNECT THE RANGE TO GAS
Gas Pipe and Electric Outlet Locations for Models Equipped with Sealed Burners
This area allows for flush range installation with
Shortest connection from hard pipe stub location to range hookup.
This area allows for flush range installation with
Gas Pipe and Electric Outlet Locations for Models Equipped with Standard Twin Burners
Shut off the main gas supply valve before disconnecting the old range and leave it off until new
Because hard piping restricts movement of the range, the use of an
To prevent gas leaks, use pipe joint compound or wrap Teflon* pipe thread tape around all male (external) pipe threads.
*Teflon: Registered trademark of DuPont
This area allows for flush range installation with
through-the-wall
connection of pipe
Shortest connection from hard pipe stub location to range hookup.
This area allows for flush range installation with
(continued next page)
31