Installation Instructions
A3
Cutout for Single Built-In Oven Under Counter
Gas or electric cooktops may be installed over this oven. See cooktop installation instructions for cutout size. See label on top of oven for approved cooktop models.
25”
(63.5 cm)
240V / 208V Junction Box Location
Gas and electrical connections for
30” (76.2 cm) gas cooktop must be located in an adjacent accessible location to the right. For 36” (91.4 cm) gas cooktop, the connections may be made to the left.
5”
(12.7 cm)
Top and/or side fillers may be necessary
if unit is positioned between existing cabinets. Be sure they are attached securely, since they will anchor the oven in the cabinet.
28 1/2”
(72.4 cm) Min.
28 5/8”
(72.6 cm) Max.
27 1/4”
(69.2 cm) Min.
27 5/16”
(69.2 cm) Max.
Allow 1” (2.5 cm) |
|
|
|
|
22” (55.9 cm) |
| 36” (91.4 cm) | ||
overlap top of |
| |||
| Typical | |||
Min. Above |
| |||
oven and |
| |||
| Countertop | |||
Support |
| |||
11/16” (1.8 cm) |
| |||
| Height | |||
Platform |
| |||
overlap side |
| |||
|
| |||
|
|
|
| |
edges of |
|
|
|
|
cutout |
| 24” |
|
|
|
|
|
| |
|
| (61 cm) |
|
|
3/4” (1.9 cm)
Support Platform
Required
MUST SUPPORT 175 LBS.
(78.8 KG)
5 9/16” (14.2 cm)
Reference dimension for maximum support height with typical 36” (91.4 cm) countertop height
This oven is not approved to be installed under a solid disk, induction or downdraft modular cooktop. See the label on the top of the oven for approved models.
7