Electrical Connections

Installation Instructions

B

Electrical Connections

ATTENTION INSTALLER

All electric wall ovens must be hard wired (direct wired) into an approved junction box. A plug and receptacle is NOT permitted on these products.

DO NOT shorten the flexible conduit. The conduit strain relief clamp must be securely attached to the junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will not fit within the clamp, do not install the oven until a clamp of the proper size is obtained.

NOTE TO ELECTRICIAN: The 3 power leads supplied with this appliance are UL recognized for connection to heavier gauge household wiring. The insulation of these 3 leads is rated at temperatures much higher than the temperature rating of household wiring. The current carrying capacity of the conductor is governed by the wire gauge and the temperature rating of the insulation around the wire.

 WARNING: Improper WARNING: Improper

connection of aluminum house wiring to copper leads can

result in an electrical hazard or fire. Use only connectors designed for joining copper to aluminum and follow the manufacturer’s recommended procedure closely.

AVERTISSEMENT :

Le raccordement inadéquat d’un câblage résidentiel en aluminium

àdes fils de sortie en cuivre peut entraîner un risque électrique ou d’incendie. Utilisez uniquement des connecteurs conçus pour raccorder du cuivre à l’aluminium et respectez minutieusement la procédure recommandée par le fabricant.

10

B1

Turn off the circuit breaker or remove

 

fuses to the oven branch circuit.

 

 

 

 

With the oven supported on a table

B2

or platform in front of the cabinet

 

 

 

 

opening, connect the flexible conduit

 

to the electrical junction box as shown

 

below. Position the conduit in such a

 

manner that it will lie on top of the

 

oven in a natural loop when the oven

 

is installed. You will need to purchase

 

an appropriate strain relief clamp to

 

complete the connection of the conduit

 

to the junction box.

 

 

 

 

 

 

Junction Box

5

 

 

 

Location

 

 

 

Conduit

(12.7cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

48 1/2

 

 

 

 

GROUND

 

(123 cm)

 

 

 

 

WIRE

 

long

 

 

 

 

 

 

BARE

 

 

GROUND

RED

 

 

WHITE

 

 

BLACK

Place oven on a

Strain Relief Clamp

(not included)

support to assist in

must be used at

connecting conduit

Junction Box