Installation Instructions
B
Electrical Connections
ATTENTION INSTALLER
All electric wall ovens must be hard wired (direct wired) into an approved junction box. A plug and receptacle is NOT permitted on these products.
DO NOT shorten the flexible conduit. The conduit strain relief clamp must be securely attached to the junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will not fit within the clamp, do not install the oven until a clamp of the proper size is obtained.
NOTE TO ELECTRICIAN: The 3 power leads supplied with this appliance are UL recognized for connection to heavier gauge household wiring. The insulation of these 3 leads is rated at temperatures much higher than the temperature rating of household wiring. The current carrying capacity of the conductor is governed by the wire gauge and the temperature rating of the insulation around the wire.
WARNING: Improper
connection of aluminum house wiring to copper leads can
result in an electrical hazard or fire. Use only connectors designed for joining copper to aluminum and follow the manufacturer’s recommended procedure closely.
AVERTISSEMENT :
Le raccordement inadéquat d’un câblage résidentiel en aluminium
àdes fils de sortie en cuivre peut entraîner un risque électrique ou d’incendie. Utilisez uniquement des connecteurs conçus pour raccorder du cuivre à l’aluminium et respectez minutieusement la procédure recommandée par le fabricant.
10
B1 | Turn off the circuit breaker or remove | ||||||
| fuses to the oven branch circuit. |
| |||||
|
| ||||||
| With the oven supported on a table | ||||||
B2 | |||||||
or platform in front of the cabinet |
| ||||||
|
| ||||||
| opening, connect the flexible conduit | ||||||
| to the electrical junction box as shown | ||||||
| below. Position the conduit in such a | ||||||
| manner that it will lie on top of the | ||||||
| oven in a natural loop when the oven | ||||||
| is installed. You will need to purchase | ||||||
| an appropriate strain relief clamp to | ||||||
| complete the connection of the conduit | ||||||
| to the junction box. |
|
|
|
| ||
|
| Junction Box | 5” |
| |||
|
| Location |
|
| |||
| Conduit | (12.7cm) |
|
| |||
|
|
|
| ||||
|
|
|
|
|
| ||
| 48 1/2” |
|
|
|
| GROUND | |
| (123 cm) |
|
|
|
| WIRE | |
| long |
|
|
|
|
|
| BARE |
|
| GROUND | RED |
|
| WHITE |
|
| BLACK |
Place oven on a | Strain Relief Clamp | |
(not included) | ||
support to assist in | must be used at | |
connecting conduit | Junction Box |
(Continued on following page)