Image 5
A1 Cutout for Single Built-In Oven

Installation Instructions

A1 Cutout for Single Built-In Oven

 

Cutout

 

 

 

 

 

Width

 

 

Cabinet Width

30(76.2 cm)

 

28 1/2Min.

 

 

 

28 5/8Max.

5"

 

 

 

 

(72.4 to

 

 

 

 

(12.7 cm)

Recommended

 

 

72.7 cm)

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

 

Junction Box

Cutout Location

 

 

 

 

Location

from Floor

32 1/2(82.6 cm)

 

 

 

 

Allow 11/16

Opening

 

 

Cutout Depth

23 1/2(59.7 cm) Min.

(1.75 cm) for

 

 

 

 

overlap of oven

Between

Cutout

22(55.9 cm)

Cutout Width

28 1/2(72.4 cm) Min.

over side edges

Inside Walls

 

 

 

 

 

of cutout

Must Be

Height

to Bottom of

 

28 5/8(72.7 cm) Max.

 

At Least

27 1/4Min.

 

 

Junction Box

 

 

28 1/2

27 5/16Max.

 

 

 

 

 

 

 

(72.4 cm)

(69.2 to 69.3 cm)

 

Cutout Height

27 1/4(69.2 cm) Min.

 

Wide

 

 

21

 

 

 

 

27 5/16(69.2 cm) Max.

(53.3 cm)

 

 

 

 

 

 

 

Recommended

 

NOTE: If the cabinet does

 

Allow 1(2.5 cm)

minimum cutout

 

 

minimum for

location from

 

not have a front frame and

 

overlap of oven

floor 32 1/2(82.6 cm)

Allow a minimum

the sides are less than 3/4

top and 114

 

 

of 21(53.3 cm) for

(3.2 cm) overlap

 

 

(1.9 cm) thick, shim both

clearance to adjacent

 

 

of oven bottom

 

 

corners, drawers,

 

 

sides equally to establish

of cutout

 

 

walls, etc. when

Cabinet

 

 

the cutout width.

door is open

 

 

 

Width

 

 

 

 

 

30(76.2 cm)

 

 

 

 

If the cabinet does not have a solid bottom, two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven. For single ovens, the runners and braces must support 175 lbs. (79 kg).

NOTE: If marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered.

Suitable

Bracing to Support Runners

C

L

215/8

(54.9 cm)

Over Centerline

of Cabinet

Install a solid bottom or 2x 4

(5 cm x 10 cm) or equivalent runners level with bottom of cutout

The solid bottom or runners must be level with the bottom of the cutout, or the bottom trim may not install correctly and then interfere with the door opening.

This oven is not approved for stackable or side by side installation.