GE ZGU384N Installation Options, Cooktop Requirements, Base Cabinet Requirements, Power Supply

Models: ZGU384NSMSS ZGU384L ZGU384LSMSS ZGU384N

1 36
Download 36 pages 24.36 Kb
Page 12
Image 12
Installation Options

Installation Options

COOKTOP INSTALLATION WITH A

30MONOGRAM DOWNDRAFT VENT,

MODEL ZVB30

The installation of the downdraft vent with this cooktop requires careful consideration. Both the cooktop and the vent must be installed according to each specific installation instruction.

COOKTOP REQUIREMENTS

The countertop must have a deep flat surface to accommodate the cooktop and vent . Countertops with a rolled front edge and backsplash will not provide the flat surface area required.

Review the illustration to determine the countertop surface requirements.

All cutout clearances for this installation must be observed.

 

30-3/4

 

 

28-1/2vent cutout

 

2-3/4

 

1/8

22-3/8

 

gap

 

 

cutout

28-1/2cooktop

23-7/8

depth

area cutout

total flat

19-5/8

 

surface

cooktop

7/16cooktop overlap

required

cutout

at center

depth

(1-1/4at center)

 

2-7/8min. cooktop cutout to rear vertical combustible surface

COOKTOP INSTALLATION WITH A Front edge of countertop COOKTOP REQUIREMENTSBASE CABINET REQUIREMENTS 2-1/2min. clearance

to cutout

12min. cutout to

wall, both sides

BASE CABINET REQUIREMENTS

The combined installation will fit in a standard 24deep base cabinet . Use a 30or wider base cabinet .

The vent housing, blower and ductwork will occupy the base cabinet .

POWER SUPPLY

If local codes permit, the vent and cooktop may operate from the same 120V, 15 amp duplex outlet . Locate the gas and electrical supply as shown on page 8.