Connect electrical (continued)
Installation
• When connecting to a
– Connect oven red lead to branch circuit red lead.
– Connect oven black lead to branch circuit black lead.
– Connect oven bare copper conductor and white lead to branch circuit neutral lead (white or gray).
• When connecting to a
– Connect oven red lead to branch circuit red lead.
– Connect oven black lead to branch circuit black lead.
– Break connection between oven white lead and oven bare copper conductor.
– Connect oven white lead to branch circuit neutral lead (white or gray).
– Connect oven bare copper conductor to branch circuit ground lead (green or bare copper).
Note: Aluminum house wiring requires use of special
19