Questions? Use this problem solver!
|
|
| The Problem Solver |
| |
|
|
|
|
|
|
|
|
|
| Built - In Refrigerators |
|
|
|
|
| ||
| PROBLEM | POSSIBLE CAUSE |
| ||
|
|
|
|
| |
| Ice clumps form | • | If you don’t use the ice very often, ice clumps may form |
| |
| in the storage bin |
| in the storage bin and can clog the dispenser. Remove the |
| |
|
|
| storage bin from the freezer and break up ice clumps with |
| |
|
|
| your hands. Throw away any clumps that you can’t break up. |
| |
|
|
|
|
| |
| Water dispenser | • | Water supply line turned off or not connected. |
| |
| does not work | • | Supply line may be clogged with sediment. |
| |
|
| • | If no water is dispensed when the icemaker is first installed, |
| |
|
|
| there may be air in the water system. Press the dispenser pad |
| |
|
|
| for at least two minutes to remove trapped air from the |
| |
|
|
| water line and to fill the water system. |
| |
|
|
|
|
| |
| Moisture forms on | • | Not unusual during periods of high humidity. If problem |
| |
| cabinet surface |
| persists, call for service. |
| |
| between the doors |
|
|
|
|
|
|
|
|
| |
| Moisture | • | Too frequent or too long door openings. |
| |
| collects inside | • | In humid weather, air carries moisture into refrigerator |
| |
|
|
| when doors are opened. |
| |
|
|
|
|
| |
| Water on the floor | • | If you use a glass over 6 inches tall, you may be jamming the |
| |
|
|
| cubes in the funnel chute. They can fuse inside the chute |
| |
|
|
| and drop out later, leaving water or ice on the floor. |
| |
|
|
|
|
| |
| Rrefrigerator has odor | • | Foods with strong odors should be tightly covered. |
| |
|
| • | Check for spoiled food. |
| |
|
| • | Interior needs cleaning. |
| |
|
| • | Keep open box of baking soda in refrigerator; replace every |
| |
|
|
| 3 months. |
| |
|
|
|
|
| |
| Interior light does | • | No power at outlet. Call installer or electrician. |
| |
| not work | • | Light bulb needs replacing. |
| |
|
| • | Check fuse and circuit breaker. |
| |
|
|
|
|
| |
| Uneven spacing or | • | Kitchen cabinets are not level or square. Call the |
| |
| gaps between doors |
| installer or cabinetmaker. |
| |
| and kitchen cabinet |
|
|
|
|
|
|
|
|
| |
| Poor door alignment | • | Refrigerator not level. Adjust leveling legs so refrigerator |
| |
| or one door higher |
| is resting solidly on the floor and is level side to side |
| |
| than the other |
| and front to back. |
| |
|
|
|
|
|
|
If you need more help…call toll free: GE Answer Center®, 800.626.2000 consumer information service
23