Planning Information
PRODUCT DIMENSIONS AND CLEARANCES
Depth Including Handles
These Monogram
Air Circulation Clearances:
•1/8" on each side
•1/2" at the back side
Installation in a corner:
•Allow 4" clearance on each side to an adjacent wall for a 90° opening and access to drawers.
•Allow 15" clearance to wall on each side for removal of drawers.
THE INSTALLATION SPACE
The opening width must be at least 36".
36" min.
Wall View
Electrical
Area
70" min.
Water Supply
Water And Electrical Locations
The opening must be prepared with the electrical and water supply located as shown.
Additional Specifications
•A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded
NOTE: GFI (ground fault interrupter) is not recommended.
•The cold water line can enter the opening through the floor or through an adjacent cabinet, as close to the back
wall as possible. The water line should be GE SmartConnect™ Refrigerator Tubing or 1/4" O.D. copper tubing between the cold water line and water connection location at the rear of the refrigerator. Installation of an easily accessible shut off valve in the water line is recommended.
3