![](/images/new-backgrounds/1073010/7301021x1.webp)
Installation Instructions
STEP 9 REPLACE FRESH FOOD DOORS
A. Lower the refrigerator door onto the center hinge pin. Ensure that the plastic hinge pin thimble is on the center hinge pin or inside door hinge pin hole located in the bottom of the door.
Hinge Pin
B. Securely tape the door shut with masking tape or have a second person support the door.
C. Insert the top hinge pin into the hinge hole on top of the refrigerator door. Make sure the door is aligned with the cabinet and opposite door. Attach the hinge to the top of the cabinet loosely with the bolts.
D. Make sure the gasket on the door is flush against the cabinet and is not folded. Make sure the door is straight and the gap between the doors is even across the front. While holding the aligned door in place, tighten the top hinge bolts.
Gasket Flush and Not Folded
Tighten Top
Hinge Bolts
E.Follow the same procedure on the opposite door.
F.Reinstall the top cap using the 4 screws removed earlier.
Top Cap Screws
STEP 10 INSTALL WATER LINE
•A cold water supply is required for automatic icemaker operation. The water pressure must be between 40 and 120 p.s.i.
•Route GE SmartConnect™ Refrigerator Tubing or 1/4" OD copper tubing between house cold water line and the water connection location.
•Measure the distance from the water valve on the back of the refrigerator to the water supply line. Add 8 foot length to allow the refrigerator to be moved away from the wall after installation. Bend the tubing into 3 coils of about 10".
NOTE: The only GE approved plastic tubing is supplied in GE SmartConnect™ Refrigerator Tubing kits. Do not use any other plastic water supply line because the line is under pressure at all times. Certain types of plastic will crack or rupture with age and cause water damage to your home.
GE SmartConnect™ Refrigerator Tubing Kits are available in the following lengths:
2' (0.6 m) | – WX08X10002 |
6' (1.8 m) | – WX08X10006 |
15' (4.6 m) | – WX08X10015 |
25' (7.6 m) | – WX08X10025 |
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the line of water.
•Install a
•Turn on the main water supply and flush debris. Run about a quart of water through the tubing into a bucket. Shut off water supply at the
NOTE: Saddle type
in many water supply kits, but are not recommended for this application.
NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use is not permitted in Massachusetts. Consult with your licensed plumber.
11