Installation Preparation
Built-In Compactors
Option #3
3/4" Thick Wood Panel with custom handle
•Cut panel 12" wide x
Go to Step 7, page 14. Follow procedure D for installation.
Note: 3/4" thick door panels, both raised and flat design, should be constructed in the same manner as typical cabinet doors. Order the 3/4" custom door panel from the cabinet manufacturer. Be sure to provide the exact dimensions so that the panel is constructed accurately. Order custom handle to match cabinetry hardware.
3/4"
12"
Power supply
CAUTION
For personal safety, do not use an extension cord or adapter plug with this appliance.
Do not, under any circumstances, cut or remove the third grounding prong from the power cord.
MISE EN GARDE
Pour votre sécurité personnelle, n’utilisez pas de rallonge ou de fiche d’adaptation avec cet appareil.
Ne coupez ou n’enlevez pas, pour quelque motif que ce soit, la troisième broche de masse du cordon d’alimentation.
Follow national electrical codes or prevailing local codes and ordinances.
Note: The outlet location is critical for proper cord storage when compactor is installed.
This appliance must be supplied with 120V, 60HZ and connected to an individual, properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse.
Install a | Note: Usable power cord |
rear wall of the cabinet opening. | length is 3 to 4 ft. |
5