Technical data

Choosing the location

 

Installation

 

Built-In Compactors

Tools required:

 

• #2 Phillips head screwdriver

 

• Flat blade screwdriver

 

• Tape measure

 

• Spirit level

 

• 10" long 2x4

 

• Adjustable wrench or slip

 

joint pliers

 

• Drill and 1/8" drill bit

 

Parts List:

 

• 4 leveling feet caps

 

• 4 Phillips head screws

 

• 2 Slotted head screws

 

• 2 Tip-over brackets

 

• 2 90° clips

 

Optional Materials

 

(not supplied):

 

• Custom front panel

 

• Custom handle

 

• Custom toekick board

 

• 5 wood screws

 

Electric Power—120V, 60 HZ, 5 amp

Container volume—1.4 cu. ft.

Circuit Requirement—15 or 20 amp grounded outlet

Weight—135 lbs.

Motor Horsepower—1/3

Cycle Time—70 sec. max., 12 sec. min.

Compacting Force—5000# max.

 

This compactor is designed as a built-in appliance

 

only. It may be located in any convenient space under

 

a countertop. DO NOT OPERATE FREE-STANDING

 

because the compactor will tip over when the drawer

 

is pulled out.

 