INSTALLATION INSTRUCTIONS
(continued)
DRAIN PUMP
•When the drain connection is above the level of the icemaker, a drain pump may be used to lift the water to an available drain. See your local dealer/plumber for recommendations.
•Pumps that fit this installation include Little Giant models VCM15ULS and VCC20ULS as well as Beckett model
NOTE: The GE warranty only covers the icemaker. Accessory drain pumps are covered by the drain pump manufacturer’s warranty.
CHECK OPERATION
•Start the icemaker by turning the service switch to “ON” and opening the line water valve.
•NOTE: Left is
•Check the condenser fan to make sure it is revolving.
•Water will not enter the pump pan until the freezing plate gets cold and the icemaker goes into a harvest cycle.
•Check for even water flow over the freezing plate. The icemaker must be level for proper operation.
•Check for desired cube thickness and after 24 hours adjust if necessary. Maximum ice yield will be obtained with ice thickness at 1/2″ to 5/8″.
•Replace the grille.
18