GE Monogram ZET857SYSS, ZET837SYSS Installation, Built-In Convection Ovens, Jumper, Loosen Screws

Models: ZET857BYBB ZET857DYSB ZET857WYWW ZET837BYBB ZET837WYWW ZET857SYSS ZET837DYSB ZET837SYSS

1 16
Download 16 pages 21.27 Kb
Page 10
Image 10
3  4  5

208V Electrical supply

Single ovens, double ovens– (upper oven)

Installation

30" Built-In Convection Ovens

 

 

WARNING

These ovens are pre-wired for connec-

If connecting to a 208 volt, 60 Hz., supply, a jumper

 

tion to 240 volt, 60 Hz., supply. If connecting

must be used across two terminals.

 

• For double ovens, there are two jumpers, one for the

 

to a 208 volt supply, modifications must be made.

 

upper oven, one for the lower oven.

 

 

 

 

 

 

 

 

• For single ovens there is one jumper.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Jumper

2

 

Loosen Screws

3 JumperLoosen ScrewsJumper Tighten ScrewsManual backgroundManual background 4 Manual backgroundManual background 5 Manual backgroundManual background

Jumper

Loosen Screws

Double ovens– (lower oven)

Jumper

Tighten Screws

To connect to 208 volt circuit:

• Remove the jumper and place between the first and

• Remove the access panel(s) located on the back of

second screws, tighten the screws to hold the

the ovens.

jumper in place.

• Loosen the first and second screws in the terminal

• Replace the access panel(s).

block as shown.

 

Double ovens–Lower

 

1

2

3

4

 

 

 

 

 

Loosen Screws

Jumper

 

 

 

 

Loosen Screws

Jumper

 

 

Jumper Tighten Screws

10

Page 10
Image 10