Installation
30"
Electrical supply
•Junction box
•Electrical
•U.L. listed conduit connector
•Wire cutters and wire stripper
Note: Do not use an extension cord with these appliances.
Do not shorten the flexible power cable.
These Monogram
Double ovens are rated 6.3 KW at 240 volt, and 5.1 KW at 208 volt.
Single ovens are rated 3.3 KW at 240 volt, and 2.8 KW at 208 volt.
WARNING
Electrical Shock Hazard
• The electrical power to the oven branch circuit must be shut off while line connections are being made.
• Use copper wiring only.
•Electrical ground is required on this appliance. The free end of the green wire (the ground wire) must be connected to a suitable ground.
This wire must remain grounded to the oven.
•If cold water pipe is interrupted by plastic, non- metallic gaskets, union connections or other insulating materials, DO NOT use for grounding.
•DO NOT ground to a gas pipe.
•DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in the NEUTRAL or GROUNDING circuit could result in an electrical shock.
•Check with a qualified electrician if you are in doubt as to whether the appliance is properly
grounded.
Failure to follow these instructions could result in serious injury or death.
Step 2
Install junction box
The conduit is located in the center at the top rear of the oven.
For double oven:
•Locate and install the junction box within reach of the power cable.
–Through the left or right of cabinet wall into adjacent cabinet.
–or, below the cutout floor.
–or, above the cutout, into the top cabinet.
For single oven:
•Locate and install the junction box within reach of the power cable.
–Below the cutout floor.
–Or, through the left or right of cabinet wall into adjacent cabinet.
–or, above the cutout, into the top cabinet.
23" | ||
Min. | ||
Min. | ||
|
Double Oven: | Single Oven: |
Locate Junction Box | Locate Junction Box |
in one of the locations | in one of the locations |
9