Electrical supply

Installation

30" Built-In Convection Ovens

Electrical supply

Junction box

Electrical cable—3-conductor or 4-conductor wire—as required by local codes

U.L. listed conduit connector

Wire cutters and wire stripper

Note: Do not use an extension cord with these appliances.

Do not shorten the flexible power cable.

These Monogram built-in ovens require a separate, properly grounded 3-wire 120/208 or 120/240 volt, 60 Hz power supply, protected by a time delay fuse or circuit breaker. Ovens are supplied with a flexible power cable, which must be attached to a junction box. The cable length is 53" for both single and double conventional ovens.

Double ovens are rated 6.3 KW at 240 volt, and 5.1 KW at 208 volt.

Single ovens are rated 3.3 KW at 240 volt, and 2.8 KW at 208 volt.

WARNING

Electrical Shock Hazard

• The electrical power to the oven branch circuit must be shut off while line connections are being made.

• Use copper wiring only.

Electrical ground is required on this appliance. The free end of the green wire (the ground wire) must be connected to a suitable ground.

This wire must remain grounded to the oven.

If cold water pipe is interrupted by plastic, non- metallic gaskets, union connections or other insulating materials, DO NOT use for grounding.

DO NOT ground to a gas pipe.

DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in the NEUTRAL or GROUNDING circuit could result in an electrical shock.

Check with a qualified electrician if you are in doubt as to whether the appliance is properly

grounded.

Failure to follow these instructions could result in serious injury or death.

Step 2

Install junction box

The conduit is located in the center at the top rear of the oven.

For double oven:

Locate and install the junction box within reach of the power cable.

Through the left or right of cabinet wall into adjacent cabinet.

or, below the cutout floor.

or, above the cutout, into the top cabinet.

For single oven:

Locate and install the junction box within reach of the power cable.

Below the cutout floor.

Or, through the left or right of cabinet wall into adjacent cabinet.

or, above the cutout, into the top cabinet.

47-5/8"

23"

Min.

Min.

 

Double Oven:

Single Oven:

Locate Junction Box

Locate Junction Box

in one of the locations

in one of the locations