GE Monogram ZGU48L4D, ZGU36L6D Assemble Burners Check Ignition, Connect Electrical, Installation

Models: ZGU48L4R ZGU36L6D ZGU48L4D

1 12
Download 12 pages 33.53 Kb
Page 9
Image 9
Connect Electrical

Step6

Connect Electrical

Installation

Professional Gas Cooktops

Plug power cord into properly grounded receptacle.

Step7

Assemble

Burners,

Check

Ignition

Replace the burner bowls and burner caps.

Adjustments should not be required, unless vibration during transit or variations in local gas supply make minor adjustments neces- sary.

CAUTION: Burner adjustments must be made by a qualified technician at the time of installation. Extreme care should be used if adjustments are made after installation.

Burner flames should be blue and stable with no yellow or yellow tips, excessive noise or lifting of the flame from the burner. If any of these conditions exist, check that the air shutter or burner ports are not blocked. If one of these conditions continues, adjust the air shutter as required.

–If the flame is too yellow, there is insufficient air flow, adjust the shutter counterclockwise to increase air inlet.

–If the flame is noisy or tends to lift away from the burner, there is too much air. Turn the shutter clockwise to reduce air.

 

Igniter

Burner

 

 

Main Burner

 

Venturi (rear)

Igniter

Simmer Burner

 

Venturi (rear)

Burner

 

 

Air Shutter

Main Burner

Simmer Burner

Venturi (front)

Venturi (front)