RS-232 COMMANDS

 

System Commands

 

 

Command

Description

#ACTIVEBOLO

Activates the boot loader

#FOOFF

Disables the +5V of the DVI input channel

#FOON

Enables the +5V of the DVI input channel

 

 

#STANDBY

Enables Standby Mode

 

 

#WAKEUP

Disables Standby Mode

 

 

#ACTIVEBOLO Command

The #ACTIVEBOLO command activates the boot loader. See page 16 for more information.

Syntax:

#activebolo

Parameters:

None

Notes:

This command must be executed twice.

#FOOFF Command

The #FOOFF command disables the +5V of the DVI input channel.

Syntax:

#fooff

Parameters:

None

14

Page 17
Image 17
Gefen EXT-DVI-144DL user manual #ACTIVEBOLO Command, #FOOFF Command