| Epson | Commands | Notes |
|
| Function | (ASCII, Decimal, Hexadecimal) |
| |
|
|
|
|
|
| Select Epson Character | ASCII: ESC t n | Table selection is made from among four |
|
| Set | Dec: 27 116 n | character tables. |
|
|
| Hex: 1B 74 n | n=0: Character Table 0 |
|
|
|
| n=1: Character Table 1 |
|
|
|
| n=2: Character Table 2 |
|
|
|
| n=3: Character Table 3 |
|
|
|
| The tables designated by default are as |
|
|
|
| follows: |
|
|
|
| Character Table 0: Italic |
|
|
|
| Character Table 1: Table being selected |
|
|
|
| by "CodePage" in the MENU |
|
|
|
| Character Table 2: DLL character re- |
|
|
|
| allocation. |
|
|
|
| Character Table 3: PC 437 (USA) |
|
| Print data as character | ASCII: ESC (^ n1 n2 [data] | All [data] become printing data. All |
|
| table | Dec: 27 40 94 n1 n2 [data] | codes of |
|
|
| Hex: 1B 28 5E n1 n2 [data] | data. 00H code is ignored as Null code. |
|
|
|
| The number of printing data (in bytes) to |
|
|
|
| follow are indicated by n1 and n2. |
|
|
|
| Number of printing data (in bytes)=n1 + |
|
|
|
| [n2 x 256] |
|
| Permit printing of upper | ASCII: ESC 6 | Enables printing of characters in upper |
|
| range control codes | Dec: 27 54 | ASCII code range (128 to 159). |
|
|
| Hex: 1B 36 |
|
|
| Cancel printing of upper | ASCII: ESC 7 | Cancels ESC 6 command. |
|
| range control codes | Dec: 27 55 |
|
|
|
| Hex: 1B 37 |
|
|
| Bar Code Command |
|
|
|
| Select Bar Code Type and | ASCII: ESC DLE A m n1 ··· n8 | m is number of parameters specified: 2, |
|
| Size | Dec: 27 16 65 m n1 ··· n8 | 4, 5, 6, 7, or 8 |
|
|
| Hex: 1B 10 41 m n1 ··· n8 | n1, n2 set bar code style as follows: |
|
|
|
| n1, n2=0, 1: EAN8 |
|
|
|
| n1, n2=0, 2: EAN13 |
|
|
|
| n1, n2=1, 0: |
|
|
|
| n1, n2=1, 4: |
|
|
|
| n1, n2=2, 0: CODE 39 |
|
|
|
| n1, n2=3, 0: Interleaved 2 of 5 |
|
|
|
| n1, n2=4, 0: Code 128 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ML390/391 Turbo Printer Handbook | 87 |