Gefen GEF-3GSDI-16416 user manual 3G-SDI Output Ports 1

Models: GEF-3GSDI-16416

1 39
Download 39 pages 11.54 Kb
Page 10
Image 10

PANEL DESCRIPTIONS

Back Panel

1Reference In Connector

Connect an external reference to this connector. Bi-level (black burst) and tri- level sync are supported.

23G-SDI Output Ports (1 - 16)

Connect 3G-SDI monitors to these ports.

3Grounding Terminal

Provides a discharge path to ground in case a short circuit occurs between the “hot” lead of the power supply and the enclosure of the Matrix. The grounding wire should be attached from the grounding terminal to an approved ground path.

4RS-232 Serial Port

Connects to the RS-232 control device. The 16x16 3GSDI Matrix may be switched remotely using this port. See page 16 for more information.

5IP Control Interface

Connect the 16x16 3GSDI Matrix to a network in order to use IP control.

6110/220 AC Power Receptacles

Connect one power cord to both power receptacles. The redundant (secondary) power cable should be connected to an electrical outlet on a different circuit.

7Fuse Drawer

Each power receptacle houses a fuse drawer. Within each fuse drawer are two

(2) 250 V fuses. One fuse is active and the other is a spare.

83G-SDI Input Ports (1 - 16)

Connect 3G-SDI source devices to these ports.

9Reference Loop Connector Reference Loop connector.

7

Page 10
Image 10
Gefen GEF-3GSDI-16416 user manual 3G-SDI Output Ports 1