HSYSTEM TROUBLES

Keypad Beeps or

Zone light

System Trouble

Action

HFlashes

ON

Condition

 

 

 

 

2 Beeps

2

Fire Trouble

A problem has been detected in the Fire Circuit.

 

 

 

Call installing company for service.

2 Beeps

3

Wireless Receiver

A problem has been detected with the wireless receiver.

 

 

Trouble

Call installing company for service.

2 Beeps

4

Wireless Receiver Jam A problem has been detected with a wireless receiver.

 

 

 

Call installing company for service.

3 Beeps

1-8

Wireless Transmitter

The battery in a wireless transmitter is low and should be replaced. This transmitter is

 

 

Low Battery

on the zone corresponding to the number of the lit zone light. The replacement battery

 

 

 

for the GEM-Trans2 door/window transmitter, GEM-PIR motion detector and GEM-GB

 

 

 

glass break detector is the Duracell DL123A 3 volt lithium. (2 required for the GEM-PIR

 

 

 

and GEM-GB). The GEM-DT Dual Technology Sensor requires 4 C cell alkaline

 

 

 

batteries. Warning: Replace batteries only with the same type as specified above. Use

 

 

 

of another battery may present a risk of fire or explosion. Do not recharge or

 

 

 

disassemble battery, or dispose of in fire.

4 Beeps

1-8

Wireless Transmitter

A problem has been detected with a wireless transmitter.

 

 

Supervisory Failure

Call installing company for service

5 Beeps

1-4

Wireless Smoke

The battery in a wireless smoke detector is low and should be replaced. This wireless

 

 

Detector Low Battery

smoke detector should be marked with a number corresponding to the number of the lit

 

 

 

zone light. The replacement battery is the Duracell MN1604 9 Volt Alkaline(2 required).

 

 

 

Warning: Replace batteries only with the same type as specified above. Use of another

 

 

 

battery may present a risk of fire or explosion. Do not recharge or disassemble battery,

 

 

 

or dispose of in fire.

6 Beeps

1-4

Wireless Smoke

A problem has been detected with a wireless smoke detector.

 

 

Detector Supervisory

Call installing company for service.

 

 

Failure

 

7 Beeps

1-6

Zone Trouble

Call installing company for service.